Abra una sección para consultar sus registros publicados; los detalles técnicos permanecen plegados hasta que los necesite.
01 Cuaderno del proyecto 9 Registros publicados ⌄
A concise view of the retrofit scope, current stage, responsibilities, and next decisions.
Retrofit Packaging Line 2 while preserving controlled production handover and an auditable installed state.
Capture agreed boundaries, functional requirements, exclusions, interfaces, and acceptance criteria here.
Record verified site conditions, constraints, access arrangements, photographs, and follow-up owners.
Keep decisions, actions, owners, due dates, and unresolved questions connected to the project record.
Document the context, alternatives, decision, approver, and effect of each material engineering choice.
Record work completed, people present, tests performed, blockers, and the condition left at the end of the shift.
Preserve test observations, failed checks, corrective work, retests, and objective acceptance evidence.
Track installed revisions, backups, training, open exceptions, accepted deliverables, and final responsibilities.
02 Tareas del proyecto 4 Registros publicados ⌄
Tema: Engineering
Tarea
Review the I/O list Completada Prioridad Alta Vencimiento 7 jun 2026, 16:00
⌄
Verify addresses, signal types, and point descriptions against the electrical drawings.
Detalles publicados Estado Completada Prioridad Alta Inicio 1 jun 2026, 7:30 Vencimiento 7 jun 2026, 16:00
Tarea
Approve the network architecture En curso Prioridad Media Vencimiento 8 jun 2026, 16:00
⌄
Finalize addressing, VLANs, and PROFINET names with the site team.
Detalles publicados Estado En curso Prioridad Media Inicio 1 jun 2026, 7:30 Vencimiento 8 jun 2026, 16:00
Tema: Installation and commissioning
Tarea
Test the pressure signal loop En espera Prioridad Urgente Vencimiento 9 jun 2026, 16:00
⌄
Verify the pressure transmitter raw and engineering values from field to PLC.
Detalles publicados Estado En espera Prioridad Urgente Inicio 1 jun 2026, 7:30 Vencimiento 9 jun 2026, 16:00
Tema: Handover
Tarea
Prepare the handover package Por hacer Prioridad Alta Vencimiento 10 jun 2026, 16:00
⌄
Check as-built documents, software versions, and test reports before handover.
Detalles publicados Estado Por hacer Prioridad Alta Inicio 1 jun 2026, 7:30 Vencimiento 10 jun 2026, 16:00
03 Registros de ingeniería 179 Registros publicados ⌄
Equipo
15 ⌄
Equipo
Equipo Activo Etiqueta PLC-101 Nombre Main line controller Fabricante Siemens Modelo S7-1515-2 PN
⌄
Detalles publicados Etiqueta PLC-101 Nombre Main line controller Tipo de equipo PLC Fabricante Siemens Modelo S7-1515-2 PN Número de pieza 6ES7515-2AM02-0AB0 Número de serie SMP-2026-00001 Ubicación Main control cabinet, packaging hall Panel MCC-01 Sistema Production-line control Descripción Main line controller; a sample asset recorded with full technical data, installation location, and commissioning history. Estado Activo Fecha de instalación 1 abr 2026, 0:00 Fecha de puesta en marcha 1 may 2026, 0:00 Fin de garantía 1 may 2028, 0:00 Notas Nameplate, wiring, grounding, configuration version, and manufacturer documents were reviewed and filed in the project record.
Equipo
Equipo Activo Etiqueta HMI-101 Nombre Main operator panel Fabricante Siemens Modelo TP1200 Comfort
⌄
Detalles publicados Etiqueta HMI-101 Nombre Main operator panel Tipo de equipo hmi Fabricante Siemens Modelo TP1200 Comfort Número de pieza 6AV2124-0MC01-0AX0 Número de serie SMP-2026-00002 Ubicación Main control cabinet, packaging hall Panel MCC-01 Sistema Operator interface Descripción Main operator panel; a sample asset recorded with full technical data, installation location, and commissioning history. Estado Activo Fecha de instalación 2 abr 2026, 0:00 Fecha de puesta en marcha 2 may 2026, 0:00 Fin de garantía 2 may 2028, 0:00 Notas Nameplate, wiring, grounding, configuration version, and manufacturer documents were reviewed and filed in the project record.
Equipo
Equipo Activo Etiqueta VFD-201 Nombre Infeed conveyor drive Fabricante Siemens Modelo SINAMICS G120
⌄
Detalles publicados Etiqueta VFD-201 Nombre Infeed conveyor drive Tipo de equipo drive Fabricante Siemens Modelo SINAMICS G120 Número de pieza 6SL3210-1KE23-2UF1 Número de serie SMP-2026-00003 Ubicación Main control cabinet, packaging hall Panel MCC-01 Sistema Product transfer Descripción Infeed conveyor drive; a sample asset recorded with full technical data, installation location, and commissioning history. Estado Activo Fecha de instalación 3 abr 2026, 0:00 Fecha de puesta en marcha 3 may 2026, 0:00 Fin de garantía 3 may 2028, 0:00 Notas Nameplate, wiring, grounding, configuration version, and manufacturer documents were reviewed and filed in the project record.
Equipo
Equipo Activo Etiqueta VFD-202 Nombre Outfeed conveyor drive Fabricante Siemens Modelo SINAMICS G120
⌄
Detalles publicados Etiqueta VFD-202 Nombre Outfeed conveyor drive Tipo de equipo drive Fabricante Siemens Modelo SINAMICS G120 Número de pieza 6SL3210-1KE21-7UF1 Número de serie SMP-2026-00004 Ubicación Main control cabinet, packaging hall Panel MCC-01 Sistema Product transfer Descripción Outfeed conveyor drive; a sample asset recorded with full technical data, installation location, and commissioning history. Estado Activo Fecha de instalación 4 abr 2026, 0:00 Fecha de puesta en marcha 4 may 2026, 0:00 Fin de garantía 4 may 2028, 0:00 Notas Nameplate, wiring, grounding, configuration version, and manufacturer documents were reviewed and filed in the project record.
Equipo
Equipo Activo Etiqueta RIO-101 Nombre Remote I/O station Fabricante Siemens Modelo ET 200SP
⌄
Detalles publicados Etiqueta RIO-101 Nombre Remote I/O station Tipo de equipo remote_io Fabricante Siemens Modelo ET 200SP Número de pieza 6ES7155-6AU01-0BN0 Número de serie SMP-2026-00005 Ubicación Main control cabinet, packaging hall Panel MCC-01 Sistema Process I/O Descripción Remote I/O station; a sample asset recorded with full technical data, installation location, and commissioning history. Estado Activo Fecha de instalación 5 abr 2026, 0:00 Fecha de puesta en marcha 5 may 2026, 0:00 Fin de garantía 5 may 2028, 0:00 Notas Nameplate, wiring, grounding, configuration version, and manufacturer documents were reviewed and filed in the project record.
Equipo
Equipo Activo Etiqueta SW-CTRL-01 Nombre Managed control-network switch Fabricante Siemens Modelo SCALANCE XC208
⌄
Detalles publicados Etiqueta SW-CTRL-01 Nombre Managed control-network switch Tipo de equipo network_switch Fabricante Siemens Modelo SCALANCE XC208 Número de pieza 6GK5208-0BA00-2AC2 Número de serie SMP-2026-00006 Ubicación Main control cabinet, packaging hall Panel MCC-01 Sistema Industrial network Descripción Managed control-network switch; a sample asset recorded with full technical data, installation location, and commissioning history. Estado Activo Fecha de instalación 6 abr 2026, 0:00 Fecha de puesta en marcha 6 may 2026, 0:00 Fin de garantía 6 may 2028, 0:00 Notas Nameplate, wiring, grounding, configuration version, and manufacturer documents were reviewed and filed in the project record.
Equipo
Equipo Activo Etiqueta PT-201 Nombre Line pressure transmitter Fabricante Endress+Hauser Modelo Cerabar PMP51
⌄
Detalles publicados Etiqueta PT-201 Nombre Line pressure transmitter Tipo de equipo sensor Fabricante Endress+Hauser Modelo Cerabar PMP51 Número de pieza PMP51-AA21JA1PGJ Número de serie SMP-2026-00007 Ubicación Production line one, packaging hall Panel FIELD-01 Sistema Process instrumentation Descripción Line pressure transmitter; a sample asset recorded with full technical data, installation location, and commissioning history. Estado Activo Fecha de instalación 7 abr 2026, 0:00 Fecha de puesta en marcha 7 may 2026, 0:00 Fin de garantía 7 may 2028, 0:00 Notas Nameplate, wiring, grounding, configuration version, and manufacturer documents were reviewed and filed in the project record.
Equipo
Equipo Activo Etiqueta LT-101 Nombre Tank level transmitter Fabricante Endress+Hauser Modelo Levelflex FMP51
⌄
Detalles publicados Etiqueta LT-101 Nombre Tank level transmitter Tipo de equipo sensor Fabricante Endress+Hauser Modelo Levelflex FMP51 Número de pieza FMP51-AAAACAA Número de serie SMP-2026-00008 Ubicación Production line one, packaging hall Panel FIELD-01 Sistema Process instrumentation Descripción Tank level transmitter; a sample asset recorded with full technical data, installation location, and commissioning history. Estado Activo Fecha de instalación 8 abr 2026, 0:00 Fecha de puesta en marcha 8 may 2026, 0:00 Fin de garantía 8 may 2028, 0:00 Notas Nameplate, wiring, grounding, configuration version, and manufacturer documents were reviewed and filed in the project record.
Equipo
Equipo Activo Etiqueta XV-101 Nombre Feed emergency shutoff valve Fabricante Festo Modelo DAPS-0080
⌄
Detalles publicados Etiqueta XV-101 Nombre Feed emergency shutoff valve Tipo de equipo actuator Fabricante Festo Modelo DAPS-0080 Número de pieza DAPS-0080-090-R-F0507 Número de serie SMP-2026-00009 Ubicación Production line one, packaging hall Panel FIELD-01 Sistema Control valves Descripción Feed emergency shutoff valve; a sample asset recorded with full technical data, installation location, and commissioning history. Estado Activo Fecha de instalación 9 abr 2026, 0:00 Fecha de puesta en marcha 9 may 2026, 0:00 Fin de garantía 9 may 2028, 0:00 Notas Nameplate, wiring, grounding, configuration version, and manufacturer documents were reviewed and filed in the project record.
Equipo
Equipo Activo Etiqueta MTR-201 Nombre Main conveyor motor Fabricante ABB Modelo M3AA 132S
⌄
Detalles publicados Etiqueta MTR-201 Nombre Main conveyor motor Tipo de equipo actuator Fabricante ABB Modelo M3AA 132S Número de pieza 3GAA132001-ASE Número de serie SMP-2026-00010 Ubicación Production line one, packaging hall Panel FIELD-01 Sistema Product transfer Descripción Main conveyor motor; a sample asset recorded with full technical data, installation location, and commissioning history. Estado Activo Fecha de instalación 10 abr 2026, 0:00 Fecha de puesta en marcha 10 may 2026, 0:00 Fin de garantía 10 may 2028, 0:00 Notas Nameplate, wiring, grounding, configuration version, and manufacturer documents were reviewed and filed in the project record.
Equipo
Equipo Activo Etiqueta PANEL-101 Nombre Main control cabinet Fabricante Rittal Modelo VX25
⌄
Detalles publicados Etiqueta PANEL-101 Nombre Main control cabinet Tipo de equipo control_panel Fabricante Rittal Modelo VX25 Número de pieza VX 8806.000 Número de serie SMP-2026-00011 Ubicación Production line one, packaging hall Panel MCC-01 Sistema Power distribution and control Descripción Main control cabinet; a sample asset recorded with full technical data, installation location, and commissioning history. Estado Activo Fecha de instalación 11 abr 2026, 0:00 Fecha de puesta en marcha 11 may 2026, 0:00 Fin de garantía 11 may 2028, 0:00 Notas Nameplate, wiring, grounding, configuration version, and manufacturer documents were reviewed and filed in the project record.
Equipo
Equipo Activo Etiqueta ENG-101 Nombre Project engineering station Fabricante Dell Modelo Precision 3680
⌄
Detalles publicados Etiqueta ENG-101 Nombre Project engineering station Tipo de equipo engineering_station Fabricante Dell Modelo Precision 3680 Número de pieza PRECISION-3680-I7 Número de serie SMP-2026-00012 Ubicación Production line one, packaging hall Panel MCC-01 Sistema Engineering and maintenance Descripción Project engineering station; a sample asset recorded with full technical data, installation location, and commissioning history. Estado Activo Fecha de instalación 12 abr 2026, 0:00 Fecha de puesta en marcha 12 may 2026, 0:00 Fin de garantía 12 may 2028, 0:00 Notas Nameplate, wiring, grounding, configuration version, and manufacturer documents were reviewed and filed in the project record.
Equipo
Equipo Activo Etiqueta UPS-101 Nombre Control uninterruptible power supply Fabricante Schneider Electric Modelo Smart-UPS SRT
⌄
Detalles publicados Etiqueta UPS-101 Nombre Control uninterruptible power supply Tipo de equipo ups Fabricante Schneider Electric Modelo Smart-UPS SRT Número de pieza SRT3000XLI Número de serie SMP-2026-00013 Ubicación Production line one, packaging hall Panel MCC-01 Sistema Control power Descripción Control uninterruptible power supply; a sample asset recorded with full technical data, installation location, and commissioning history. Estado Activo Fecha de instalación 13 abr 2026, 0:00 Fecha de puesta en marcha 13 may 2026, 0:00 Fin de garantía 13 may 2028, 0:00 Notas Nameplate, wiring, grounding, configuration version, and manufacturer documents were reviewed and filed in the project record.
Equipo
Equipo Activo Etiqueta SAFE-101 Nombre Line safety controller Fabricante Pilz Modelo PNOZmulti 2
⌄
Detalles publicados Etiqueta SAFE-101 Nombre Line safety controller Tipo de equipo safety_system Fabricante Pilz Modelo PNOZmulti 2 Número de pieza 772100 Número de serie SMP-2026-00014 Ubicación Production line one, packaging hall Panel MCC-01 Sistema Machine safety Descripción Line safety controller; a sample asset recorded with full technical data, installation location, and commissioning history. Estado Activo Fecha de instalación 14 abr 2026, 0:00 Fecha de puesta en marcha 14 may 2026, 0:00 Fin de garantía 14 may 2028, 0:00 Notas Nameplate, wiring, grounding, configuration version, and manufacturer documents were reviewed and filed in the project record.
Equipo
Equipo Activo Etiqueta VISION-101 Nombre Quality-control vision system Fabricante Cognex Modelo In-Sight 7905
⌄
Detalles publicados Etiqueta VISION-101 Nombre Quality-control vision system Tipo de equipo vision_system Fabricante Cognex Modelo In-Sight 7905 Número de pieza IS7905M-363-50 Número de serie SMP-2026-00015 Ubicación Production line one, packaging hall Panel FIELD-01 Sistema Quality control Descripción Quality-control vision system; a sample asset recorded with full technical data, installation location, and commissioning history. Estado Activo Fecha de instalación 15 abr 2026, 0:00 Fecha de puesta en marcha 15 may 2026, 0:00 Fin de garantía 15 may 2028, 0:00 Notas Nameplate, wiring, grounding, configuration version, and manufacturer documents were reviewed and filed in the project record.
Software
7 ⌄
Software
Software verified Nombre Line control program
⌄
Detalles publicados Nombre Line control program Proveedor Siemens Producto TIA Portal Versión V19.0 Actualización / paquete de servicio Update 3 Versión de firmware V3.1.0 Tipo de licencia Engineering Floating Instalado en PLC-101 Última verificación 10 jun 2026, 0:00 Notas Installation media, licence, software version, and firmware compatibility were verified and recorded for controlled recovery. Estado verified
Software
Software verified Nombre Operator panel project
⌄
Detalles publicados Nombre Operator panel project Proveedor Siemens Producto WinCC Unified Versión V19.0 Actualización / paquete de servicio Update 3 Versión de firmware V19.0.0.3 Tipo de licencia Runtime Advanced Instalado en HMI-101 Última verificación 11 jun 2026, 0:00 Notas Installation media, licence, software version, and firmware compatibility were verified and recorded for controlled recovery. Estado verified
Software
Software verified Nombre Drive commissioning parameters
⌄
Detalles publicados Nombre Drive commissioning parameters Proveedor Siemens Producto Startdrive Versión V19.0 Actualización / paquete de servicio HF2 Versión de firmware V4.7.13 Tipo de licencia Engineering Instalado en VFD-201 Última verificación 12 jun 2026, 0:00 Notas Installation media, licence, software version, and firmware compatibility were verified and recorded for controlled recovery. Estado verified
Software
Software verified Nombre Industrial network configuration
⌄
Detalles publicados Nombre Industrial network configuration Proveedor Siemens Producto PRONETA Professional Versión V3.7 Actualización / paquete de servicio SP1 Versión de firmware V3.7.1 Tipo de licencia Professional Instalado en SW-CTRL-01 Última verificación 13 jun 2026, 0:00 Notas Installation media, licence, software version, and firmware compatibility were verified and recorded for controlled recovery. Estado verified
Software
Software verified Nombre Machine safety logic
⌄
Detalles publicados Nombre Machine safety logic Proveedor Pilz Producto PNOZmulti Configurator Versión V11.4 Actualización / paquete de servicio Build 184 Versión de firmware V2.6.2 Tipo de licencia Basic Instalado en SAFE-101 Última verificación 14 jun 2026, 0:00 Notas Installation media, licence, software version, and firmware compatibility were verified and recorded for controlled recovery. Estado verified
Software
Software verified Nombre Machine vision configuration
⌄
Detalles publicados Nombre Machine vision configuration Proveedor Cognex Producto In-Sight Explorer Versión V6.4.1 Actualización / paquete de servicio Patch 2 Versión de firmware V6.4.1.2 Tipo de licencia Offline Programming Instalado en VISION-101 Última verificación 15 jun 2026, 0:00 Notas Installation media, licence, software version, and firmware compatibility were verified and recorded for controlled recovery. Estado verified
Software
Software verified Nombre Backup revision management
⌄
Detalles publicados Nombre Backup revision management Proveedor AutoNexit Producto Revision Vault Exporter Versión V1.11 Actualización / paquete de servicio Release 2026.09 Versión de firmware V1.11.0 Tipo de licencia Project Instalado en ENG-101 Última verificación 16 jun 2026, 0:00 Notas Installation media, licence, software version, and firmware compatibility were verified and recorded for controlled recovery. Estado verified
Punto E/S
150 ⌄
Punto E/S
Punto E/S Activo Etiqueta DI-001
⌄
Detalles publicados Etiqueta DI-001 Descripción Sample line DI point 001 with function, scaling, and safe state recorded Dirección Entrada Tipo de señal Entrada digital Tipo de datos boolean Bastidor RACK-PLC-01 Ranura 1 Canal 0 Dirección I0.0 Mínimo de ingeniería 0.000000 Máximo de ingeniería 1.000000 Unidad state Mínimo bruto 0.000000 Máximo bruto 1.000000 Estado normal 0 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta DO-002
⌄
Detalles publicados Etiqueta DO-002 Descripción Sample line DO point 002 with function, scaling, and safe state recorded Dirección Salida Tipo de señal Salida digital Tipo de datos boolean Bastidor RACK-PLC-01 Ranura 1 Canal 1 Dirección Q0.1 Mínimo de ingeniería 0.000000 Máximo de ingeniería 1.000000 Unidad state Mínimo bruto 0.000000 Máximo bruto 1.000000 Estado normal 0 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta AI-003
⌄
Detalles publicados Etiqueta AI-003 Descripción Sample line AI point 003 with function, scaling, and safe state recorded Dirección Entrada Tipo de señal Entrada analógica Tipo de datos real Bastidor RACK-PLC-01 Ranura 1 Canal 2 Dirección IW68 Mínimo de ingeniería 0.000000 Máximo de ingeniería 100.000000 Unidad % Mínimo bruto 0.000000 Máximo bruto 27648.000000 Estado normal 50 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta AO-004
⌄
Detalles publicados Etiqueta AO-004 Descripción Sample line AO point 004 with function, scaling, and safe state recorded Dirección Salida Tipo de señal Salida analógica Tipo de datos real Bastidor RACK-PLC-01 Ranura 1 Canal 3 Dirección QW70 Mínimo de ingeniería 0.000000 Máximo de ingeniería 100.000000 Unidad % Mínimo bruto 0.000000 Máximo bruto 27648.000000 Estado normal 50 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta RTD-005
⌄
Detalles publicados Etiqueta RTD-005 Descripción Sample line RTD point 005 with function, scaling, and safe state recorded Dirección Entrada Tipo de señal rtd Tipo de datos real Bastidor RACK-PLC-01 Ranura 1 Canal 4 Dirección IW72 Mínimo de ingeniería 0.000000 Máximo de ingeniería 100.000000 Unidad °C Mínimo bruto 0.000000 Máximo bruto 27648.000000 Estado normal 50 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta PULSE-006
⌄
Detalles publicados Etiqueta PULSE-006 Descripción Sample line PULSE point 006 with function, scaling, and safe state recorded Dirección Salida Tipo de señal pulse Tipo de datos boolean Bastidor RACK-PLC-01 Ranura 1 Canal 5 Dirección Q0.5 Mínimo de ingeniería 0.000000 Máximo de ingeniería 1.000000 Unidad state Mínimo bruto 0.000000 Máximo bruto 1.000000 Estado normal 0 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta DI-007
⌄
Detalles publicados Etiqueta DI-007 Descripción Sample line DI point 007 with function, scaling, and safe state recorded Dirección Entrada Tipo de señal Entrada digital Tipo de datos boolean Bastidor RACK-PLC-01 Ranura 1 Canal 6 Dirección I0.6 Mínimo de ingeniería 0.000000 Máximo de ingeniería 1.000000 Unidad state Mínimo bruto 0.000000 Máximo bruto 1.000000 Estado normal 0 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta DO-008
⌄
Detalles publicados Etiqueta DO-008 Descripción Sample line DO point 008 with function, scaling, and safe state recorded Dirección Salida Tipo de señal Salida digital Tipo de datos boolean Bastidor RACK-PLC-01 Ranura 1 Canal 7 Dirección Q0.7 Mínimo de ingeniería 0.000000 Máximo de ingeniería 1.000000 Unidad state Mínimo bruto 0.000000 Máximo bruto 1.000000 Estado normal 0 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta AI-009
⌄
Detalles publicados Etiqueta AI-009 Descripción Sample line AI point 009 with function, scaling, and safe state recorded Dirección Entrada Tipo de señal Entrada analógica Tipo de datos real Bastidor RACK-PLC-01 Ranura 1 Canal 8 Dirección IW80 Mínimo de ingeniería 0.000000 Máximo de ingeniería 100.000000 Unidad % Mínimo bruto 0.000000 Máximo bruto 27648.000000 Estado normal 50 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta AO-010
⌄
Detalles publicados Etiqueta AO-010 Descripción Sample line AO point 010 with function, scaling, and safe state recorded Dirección Salida Tipo de señal Salida analógica Tipo de datos real Bastidor RACK-PLC-01 Ranura 1 Canal 9 Dirección QW82 Mínimo de ingeniería 0.000000 Máximo de ingeniería 100.000000 Unidad % Mínimo bruto 0.000000 Máximo bruto 27648.000000 Estado normal 50 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta RTD-011
⌄
Detalles publicados Etiqueta RTD-011 Descripción Sample line RTD point 011 with function, scaling, and safe state recorded Dirección Entrada Tipo de señal rtd Tipo de datos real Bastidor RACK-PLC-01 Ranura 1 Canal 10 Dirección IW84 Mínimo de ingeniería 0.000000 Máximo de ingeniería 100.000000 Unidad °C Mínimo bruto 0.000000 Máximo bruto 27648.000000 Estado normal 50 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta PULSE-012
⌄
Detalles publicados Etiqueta PULSE-012 Descripción Sample line PULSE point 012 with function, scaling, and safe state recorded Dirección Salida Tipo de señal pulse Tipo de datos boolean Bastidor RACK-PLC-01 Ranura 1 Canal 11 Dirección Q1.3 Mínimo de ingeniería 0.000000 Máximo de ingeniería 1.000000 Unidad state Mínimo bruto 0.000000 Máximo bruto 1.000000 Estado normal 0 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta DI-013
⌄
Detalles publicados Etiqueta DI-013 Descripción Sample line DI point 013 with function, scaling, and safe state recorded Dirección Entrada Tipo de señal Entrada digital Tipo de datos boolean Bastidor RACK-PLC-01 Ranura 1 Canal 12 Dirección I1.4 Mínimo de ingeniería 0.000000 Máximo de ingeniería 1.000000 Unidad state Mínimo bruto 0.000000 Máximo bruto 1.000000 Estado normal 0 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta DO-014
⌄
Detalles publicados Etiqueta DO-014 Descripción Sample line DO point 014 with function, scaling, and safe state recorded Dirección Salida Tipo de señal Salida digital Tipo de datos boolean Bastidor RACK-PLC-01 Ranura 1 Canal 13 Dirección Q1.5 Mínimo de ingeniería 0.000000 Máximo de ingeniería 1.000000 Unidad state Mínimo bruto 0.000000 Máximo bruto 1.000000 Estado normal 0 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta AI-015
⌄
Detalles publicados Etiqueta AI-015 Descripción Sample line AI point 015 with function, scaling, and safe state recorded Dirección Entrada Tipo de señal Entrada analógica Tipo de datos real Bastidor RACK-PLC-01 Ranura 1 Canal 14 Dirección IW92 Mínimo de ingeniería 0.000000 Máximo de ingeniería 100.000000 Unidad % Mínimo bruto 0.000000 Máximo bruto 27648.000000 Estado normal 50 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta AO-016
⌄
Detalles publicados Etiqueta AO-016 Descripción Sample line AO point 016 with function, scaling, and safe state recorded Dirección Salida Tipo de señal Salida analógica Tipo de datos real Bastidor RACK-PLC-01 Ranura 1 Canal 15 Dirección QW94 Mínimo de ingeniería 0.000000 Máximo de ingeniería 100.000000 Unidad % Mínimo bruto 0.000000 Máximo bruto 27648.000000 Estado normal 50 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta RTD-017
⌄
Detalles publicados Etiqueta RTD-017 Descripción Sample line RTD point 017 with function, scaling, and safe state recorded Dirección Entrada Tipo de señal rtd Tipo de datos real Bastidor RACK-PLC-01 Ranura 2 Canal 0 Dirección IW96 Mínimo de ingeniería 0.000000 Máximo de ingeniería 100.000000 Unidad °C Mínimo bruto 0.000000 Máximo bruto 27648.000000 Estado normal 50 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta PULSE-018
⌄
Detalles publicados Etiqueta PULSE-018 Descripción Sample line PULSE point 018 with function, scaling, and safe state recorded Dirección Salida Tipo de señal pulse Tipo de datos boolean Bastidor RACK-PLC-01 Ranura 2 Canal 1 Dirección Q2.1 Mínimo de ingeniería 0.000000 Máximo de ingeniería 1.000000 Unidad state Mínimo bruto 0.000000 Máximo bruto 1.000000 Estado normal 0 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta DI-019
⌄
Detalles publicados Etiqueta DI-019 Descripción Sample line DI point 019 with function, scaling, and safe state recorded Dirección Entrada Tipo de señal Entrada digital Tipo de datos boolean Bastidor RACK-PLC-01 Ranura 2 Canal 2 Dirección I2.2 Mínimo de ingeniería 0.000000 Máximo de ingeniería 1.000000 Unidad state Mínimo bruto 0.000000 Máximo bruto 1.000000 Estado normal 0 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta DO-020
⌄
Detalles publicados Etiqueta DO-020 Descripción Sample line DO point 020 with function, scaling, and safe state recorded Dirección Salida Tipo de señal Salida digital Tipo de datos boolean Bastidor RACK-PLC-01 Ranura 2 Canal 3 Dirección Q2.3 Mínimo de ingeniería 0.000000 Máximo de ingeniería 1.000000 Unidad state Mínimo bruto 0.000000 Máximo bruto 1.000000 Estado normal 0 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta AI-021
⌄
Detalles publicados Etiqueta AI-021 Descripción Sample line AI point 021 with function, scaling, and safe state recorded Dirección Entrada Tipo de señal Entrada analógica Tipo de datos real Bastidor RACK-PLC-01 Ranura 2 Canal 4 Dirección IW104 Mínimo de ingeniería 0.000000 Máximo de ingeniería 100.000000 Unidad % Mínimo bruto 0.000000 Máximo bruto 27648.000000 Estado normal 50 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta AO-022
⌄
Detalles publicados Etiqueta AO-022 Descripción Sample line AO point 022 with function, scaling, and safe state recorded Dirección Salida Tipo de señal Salida analógica Tipo de datos real Bastidor RACK-PLC-01 Ranura 2 Canal 5 Dirección QW106 Mínimo de ingeniería 0.000000 Máximo de ingeniería 100.000000 Unidad % Mínimo bruto 0.000000 Máximo bruto 27648.000000 Estado normal 50 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta RTD-023
⌄
Detalles publicados Etiqueta RTD-023 Descripción Sample line RTD point 023 with function, scaling, and safe state recorded Dirección Entrada Tipo de señal rtd Tipo de datos real Bastidor RACK-PLC-01 Ranura 2 Canal 6 Dirección IW108 Mínimo de ingeniería 0.000000 Máximo de ingeniería 100.000000 Unidad °C Mínimo bruto 0.000000 Máximo bruto 27648.000000 Estado normal 50 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta PULSE-024
⌄
Detalles publicados Etiqueta PULSE-024 Descripción Sample line PULSE point 024 with function, scaling, and safe state recorded Dirección Salida Tipo de señal pulse Tipo de datos boolean Bastidor RACK-PLC-01 Ranura 2 Canal 7 Dirección Q2.7 Mínimo de ingeniería 0.000000 Máximo de ingeniería 1.000000 Unidad state Mínimo bruto 0.000000 Máximo bruto 1.000000 Estado normal 0 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta DI-025
⌄
Detalles publicados Etiqueta DI-025 Descripción Sample line DI point 025 with function, scaling, and safe state recorded Dirección Entrada Tipo de señal Entrada digital Tipo de datos boolean Bastidor RACK-PLC-01 Ranura 2 Canal 8 Dirección I3.0 Mínimo de ingeniería 0.000000 Máximo de ingeniería 1.000000 Unidad state Mínimo bruto 0.000000 Máximo bruto 1.000000 Estado normal 0 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta DO-026
⌄
Detalles publicados Etiqueta DO-026 Descripción Sample line DO point 026 with function, scaling, and safe state recorded Dirección Salida Tipo de señal Salida digital Tipo de datos boolean Bastidor RACK-PLC-01 Ranura 2 Canal 9 Dirección Q3.1 Mínimo de ingeniería 0.000000 Máximo de ingeniería 1.000000 Unidad state Mínimo bruto 0.000000 Máximo bruto 1.000000 Estado normal 0 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta AI-027
⌄
Detalles publicados Etiqueta AI-027 Descripción Sample line AI point 027 with function, scaling, and safe state recorded Dirección Entrada Tipo de señal Entrada analógica Tipo de datos real Bastidor RACK-PLC-01 Ranura 2 Canal 10 Dirección IW116 Mínimo de ingeniería 0.000000 Máximo de ingeniería 100.000000 Unidad % Mínimo bruto 0.000000 Máximo bruto 27648.000000 Estado normal 50 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta AO-028
⌄
Detalles publicados Etiqueta AO-028 Descripción Sample line AO point 028 with function, scaling, and safe state recorded Dirección Salida Tipo de señal Salida analógica Tipo de datos real Bastidor RACK-PLC-01 Ranura 2 Canal 11 Dirección QW118 Mínimo de ingeniería 0.000000 Máximo de ingeniería 100.000000 Unidad % Mínimo bruto 0.000000 Máximo bruto 27648.000000 Estado normal 50 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta RTD-029
⌄
Detalles publicados Etiqueta RTD-029 Descripción Sample line RTD point 029 with function, scaling, and safe state recorded Dirección Entrada Tipo de señal rtd Tipo de datos real Bastidor RACK-PLC-01 Ranura 2 Canal 12 Dirección IW120 Mínimo de ingeniería 0.000000 Máximo de ingeniería 100.000000 Unidad °C Mínimo bruto 0.000000 Máximo bruto 27648.000000 Estado normal 50 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta PULSE-030
⌄
Detalles publicados Etiqueta PULSE-030 Descripción Sample line PULSE point 030 with function, scaling, and safe state recorded Dirección Salida Tipo de señal pulse Tipo de datos boolean Bastidor RACK-PLC-01 Ranura 2 Canal 13 Dirección Q3.5 Mínimo de ingeniería 0.000000 Máximo de ingeniería 1.000000 Unidad state Mínimo bruto 0.000000 Máximo bruto 1.000000 Estado normal 0 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta DI-031
⌄
Detalles publicados Etiqueta DI-031 Descripción Sample line DI point 031 with function, scaling, and safe state recorded Dirección Entrada Tipo de señal Entrada digital Tipo de datos boolean Bastidor RACK-PLC-01 Ranura 2 Canal 14 Dirección I3.6 Mínimo de ingeniería 0.000000 Máximo de ingeniería 1.000000 Unidad state Mínimo bruto 0.000000 Máximo bruto 1.000000 Estado normal 0 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta DO-032
⌄
Detalles publicados Etiqueta DO-032 Descripción Sample line DO point 032 with function, scaling, and safe state recorded Dirección Salida Tipo de señal Salida digital Tipo de datos boolean Bastidor RACK-PLC-01 Ranura 2 Canal 15 Dirección Q3.7 Mínimo de ingeniería 0.000000 Máximo de ingeniería 1.000000 Unidad state Mínimo bruto 0.000000 Máximo bruto 1.000000 Estado normal 0 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta AI-033
⌄
Detalles publicados Etiqueta AI-033 Descripción Sample line AI point 033 with function, scaling, and safe state recorded Dirección Entrada Tipo de señal Entrada analógica Tipo de datos real Bastidor RACK-PLC-01 Ranura 3 Canal 0 Dirección IW128 Mínimo de ingeniería 0.000000 Máximo de ingeniería 100.000000 Unidad % Mínimo bruto 0.000000 Máximo bruto 27648.000000 Estado normal 50 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta AO-034
⌄
Detalles publicados Etiqueta AO-034 Descripción Sample line AO point 034 with function, scaling, and safe state recorded Dirección Salida Tipo de señal Salida analógica Tipo de datos real Bastidor RACK-PLC-01 Ranura 3 Canal 1 Dirección QW130 Mínimo de ingeniería 0.000000 Máximo de ingeniería 100.000000 Unidad % Mínimo bruto 0.000000 Máximo bruto 27648.000000 Estado normal 50 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta RTD-035
⌄
Detalles publicados Etiqueta RTD-035 Descripción Sample line RTD point 035 with function, scaling, and safe state recorded Dirección Entrada Tipo de señal rtd Tipo de datos real Bastidor RACK-PLC-01 Ranura 3 Canal 2 Dirección IW132 Mínimo de ingeniería 0.000000 Máximo de ingeniería 100.000000 Unidad °C Mínimo bruto 0.000000 Máximo bruto 27648.000000 Estado normal 50 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta PULSE-036
⌄
Detalles publicados Etiqueta PULSE-036 Descripción Sample line PULSE point 036 with function, scaling, and safe state recorded Dirección Salida Tipo de señal pulse Tipo de datos boolean Bastidor RACK-PLC-01 Ranura 3 Canal 3 Dirección Q4.3 Mínimo de ingeniería 0.000000 Máximo de ingeniería 1.000000 Unidad state Mínimo bruto 0.000000 Máximo bruto 1.000000 Estado normal 0 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta DI-037
⌄
Detalles publicados Etiqueta DI-037 Descripción Sample line DI point 037 with function, scaling, and safe state recorded Dirección Entrada Tipo de señal Entrada digital Tipo de datos boolean Bastidor RACK-PLC-01 Ranura 3 Canal 4 Dirección I4.4 Mínimo de ingeniería 0.000000 Máximo de ingeniería 1.000000 Unidad state Mínimo bruto 0.000000 Máximo bruto 1.000000 Estado normal 0 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta DO-038
⌄
Detalles publicados Etiqueta DO-038 Descripción Sample line DO point 038 with function, scaling, and safe state recorded Dirección Salida Tipo de señal Salida digital Tipo de datos boolean Bastidor RACK-PLC-01 Ranura 3 Canal 5 Dirección Q4.5 Mínimo de ingeniería 0.000000 Máximo de ingeniería 1.000000 Unidad state Mínimo bruto 0.000000 Máximo bruto 1.000000 Estado normal 0 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta AI-039
⌄
Detalles publicados Etiqueta AI-039 Descripción Sample line AI point 039 with function, scaling, and safe state recorded Dirección Entrada Tipo de señal Entrada analógica Tipo de datos real Bastidor RACK-PLC-01 Ranura 3 Canal 6 Dirección IW140 Mínimo de ingeniería 0.000000 Máximo de ingeniería 100.000000 Unidad % Mínimo bruto 0.000000 Máximo bruto 27648.000000 Estado normal 50 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta AO-040
⌄
Detalles publicados Etiqueta AO-040 Descripción Sample line AO point 040 with function, scaling, and safe state recorded Dirección Salida Tipo de señal Salida analógica Tipo de datos real Bastidor RACK-PLC-01 Ranura 3 Canal 7 Dirección QW142 Mínimo de ingeniería 0.000000 Máximo de ingeniería 100.000000 Unidad % Mínimo bruto 0.000000 Máximo bruto 27648.000000 Estado normal 50 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta RTD-041
⌄
Detalles publicados Etiqueta RTD-041 Descripción Sample line RTD point 041 with function, scaling, and safe state recorded Dirección Entrada Tipo de señal rtd Tipo de datos real Bastidor RACK-PLC-01 Ranura 3 Canal 8 Dirección IW144 Mínimo de ingeniería 0.000000 Máximo de ingeniería 100.000000 Unidad °C Mínimo bruto 0.000000 Máximo bruto 27648.000000 Estado normal 50 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta PULSE-042
⌄
Detalles publicados Etiqueta PULSE-042 Descripción Sample line PULSE point 042 with function, scaling, and safe state recorded Dirección Salida Tipo de señal pulse Tipo de datos boolean Bastidor RACK-PLC-01 Ranura 3 Canal 9 Dirección Q5.1 Mínimo de ingeniería 0.000000 Máximo de ingeniería 1.000000 Unidad state Mínimo bruto 0.000000 Máximo bruto 1.000000 Estado normal 0 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta DI-043
⌄
Detalles publicados Etiqueta DI-043 Descripción Sample line DI point 043 with function, scaling, and safe state recorded Dirección Entrada Tipo de señal Entrada digital Tipo de datos boolean Bastidor RACK-PLC-01 Ranura 3 Canal 10 Dirección I5.2 Mínimo de ingeniería 0.000000 Máximo de ingeniería 1.000000 Unidad state Mínimo bruto 0.000000 Máximo bruto 1.000000 Estado normal 0 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta DO-044
⌄
Detalles publicados Etiqueta DO-044 Descripción Sample line DO point 044 with function, scaling, and safe state recorded Dirección Salida Tipo de señal Salida digital Tipo de datos boolean Bastidor RACK-PLC-01 Ranura 3 Canal 11 Dirección Q5.3 Mínimo de ingeniería 0.000000 Máximo de ingeniería 1.000000 Unidad state Mínimo bruto 0.000000 Máximo bruto 1.000000 Estado normal 0 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta AI-045
⌄
Detalles publicados Etiqueta AI-045 Descripción Sample line AI point 045 with function, scaling, and safe state recorded Dirección Entrada Tipo de señal Entrada analógica Tipo de datos real Bastidor RACK-PLC-01 Ranura 3 Canal 12 Dirección IW152 Mínimo de ingeniería 0.000000 Máximo de ingeniería 100.000000 Unidad % Mínimo bruto 0.000000 Máximo bruto 27648.000000 Estado normal 50 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta AO-046
⌄
Detalles publicados Etiqueta AO-046 Descripción Sample line AO point 046 with function, scaling, and safe state recorded Dirección Salida Tipo de señal Salida analógica Tipo de datos real Bastidor RACK-PLC-01 Ranura 3 Canal 13 Dirección QW154 Mínimo de ingeniería 0.000000 Máximo de ingeniería 100.000000 Unidad % Mínimo bruto 0.000000 Máximo bruto 27648.000000 Estado normal 50 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta RTD-047
⌄
Detalles publicados Etiqueta RTD-047 Descripción Sample line RTD point 047 with function, scaling, and safe state recorded Dirección Entrada Tipo de señal rtd Tipo de datos real Bastidor RACK-PLC-01 Ranura 3 Canal 14 Dirección IW156 Mínimo de ingeniería 0.000000 Máximo de ingeniería 100.000000 Unidad °C Mínimo bruto 0.000000 Máximo bruto 27648.000000 Estado normal 50 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta PULSE-048
⌄
Detalles publicados Etiqueta PULSE-048 Descripción Sample line PULSE point 048 with function, scaling, and safe state recorded Dirección Salida Tipo de señal pulse Tipo de datos boolean Bastidor RACK-PLC-01 Ranura 3 Canal 15 Dirección Q5.7 Mínimo de ingeniería 0.000000 Máximo de ingeniería 1.000000 Unidad state Mínimo bruto 0.000000 Máximo bruto 1.000000 Estado normal 0 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta DI-049
⌄
Detalles publicados Etiqueta DI-049 Descripción Sample line DI point 049 with function, scaling, and safe state recorded Dirección Entrada Tipo de señal Entrada digital Tipo de datos boolean Bastidor RACK-PLC-01 Ranura 4 Canal 0 Dirección I6.0 Mínimo de ingeniería 0.000000 Máximo de ingeniería 1.000000 Unidad state Mínimo bruto 0.000000 Máximo bruto 1.000000 Estado normal 0 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta DO-050
⌄
Detalles publicados Etiqueta DO-050 Descripción Sample line DO point 050 with function, scaling, and safe state recorded Dirección Salida Tipo de señal Salida digital Tipo de datos boolean Bastidor RACK-PLC-01 Ranura 4 Canal 1 Dirección Q6.1 Mínimo de ingeniería 0.000000 Máximo de ingeniería 1.000000 Unidad state Mínimo bruto 0.000000 Máximo bruto 1.000000 Estado normal 0 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta AI-051
⌄
Detalles publicados Etiqueta AI-051 Descripción Sample line AI point 051 with function, scaling, and safe state recorded Dirección Entrada Tipo de señal Entrada analógica Tipo de datos real Bastidor RACK-PLC-01 Ranura 4 Canal 2 Dirección IW164 Mínimo de ingeniería 0.000000 Máximo de ingeniería 100.000000 Unidad % Mínimo bruto 0.000000 Máximo bruto 27648.000000 Estado normal 50 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta AO-052
⌄
Detalles publicados Etiqueta AO-052 Descripción Sample line AO point 052 with function, scaling, and safe state recorded Dirección Salida Tipo de señal Salida analógica Tipo de datos real Bastidor RACK-PLC-01 Ranura 4 Canal 3 Dirección QW166 Mínimo de ingeniería 0.000000 Máximo de ingeniería 100.000000 Unidad % Mínimo bruto 0.000000 Máximo bruto 27648.000000 Estado normal 50 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta RTD-053
⌄
Detalles publicados Etiqueta RTD-053 Descripción Sample line RTD point 053 with function, scaling, and safe state recorded Dirección Entrada Tipo de señal rtd Tipo de datos real Bastidor RACK-PLC-01 Ranura 4 Canal 4 Dirección IW168 Mínimo de ingeniería 0.000000 Máximo de ingeniería 100.000000 Unidad °C Mínimo bruto 0.000000 Máximo bruto 27648.000000 Estado normal 50 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta PULSE-054
⌄
Detalles publicados Etiqueta PULSE-054 Descripción Sample line PULSE point 054 with function, scaling, and safe state recorded Dirección Salida Tipo de señal pulse Tipo de datos boolean Bastidor RACK-PLC-01 Ranura 4 Canal 5 Dirección Q6.5 Mínimo de ingeniería 0.000000 Máximo de ingeniería 1.000000 Unidad state Mínimo bruto 0.000000 Máximo bruto 1.000000 Estado normal 0 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta DI-055
⌄
Detalles publicados Etiqueta DI-055 Descripción Sample line DI point 055 with function, scaling, and safe state recorded Dirección Entrada Tipo de señal Entrada digital Tipo de datos boolean Bastidor RACK-PLC-01 Ranura 4 Canal 6 Dirección I6.6 Mínimo de ingeniería 0.000000 Máximo de ingeniería 1.000000 Unidad state Mínimo bruto 0.000000 Máximo bruto 1.000000 Estado normal 0 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta DO-056
⌄
Detalles publicados Etiqueta DO-056 Descripción Sample line DO point 056 with function, scaling, and safe state recorded Dirección Salida Tipo de señal Salida digital Tipo de datos boolean Bastidor RACK-PLC-01 Ranura 4 Canal 7 Dirección Q6.7 Mínimo de ingeniería 0.000000 Máximo de ingeniería 1.000000 Unidad state Mínimo bruto 0.000000 Máximo bruto 1.000000 Estado normal 0 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta AI-057
⌄
Detalles publicados Etiqueta AI-057 Descripción Sample line AI point 057 with function, scaling, and safe state recorded Dirección Entrada Tipo de señal Entrada analógica Tipo de datos real Bastidor RACK-PLC-01 Ranura 4 Canal 8 Dirección IW176 Mínimo de ingeniería 0.000000 Máximo de ingeniería 100.000000 Unidad % Mínimo bruto 0.000000 Máximo bruto 27648.000000 Estado normal 50 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta AO-058
⌄
Detalles publicados Etiqueta AO-058 Descripción Sample line AO point 058 with function, scaling, and safe state recorded Dirección Salida Tipo de señal Salida analógica Tipo de datos real Bastidor RACK-PLC-01 Ranura 4 Canal 9 Dirección QW178 Mínimo de ingeniería 0.000000 Máximo de ingeniería 100.000000 Unidad % Mínimo bruto 0.000000 Máximo bruto 27648.000000 Estado normal 50 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta RTD-059
⌄
Detalles publicados Etiqueta RTD-059 Descripción Sample line RTD point 059 with function, scaling, and safe state recorded Dirección Entrada Tipo de señal rtd Tipo de datos real Bastidor RACK-PLC-01 Ranura 4 Canal 10 Dirección IW180 Mínimo de ingeniería 0.000000 Máximo de ingeniería 100.000000 Unidad °C Mínimo bruto 0.000000 Máximo bruto 27648.000000 Estado normal 50 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta PULSE-060
⌄
Detalles publicados Etiqueta PULSE-060 Descripción Sample line PULSE point 060 with function, scaling, and safe state recorded Dirección Salida Tipo de señal pulse Tipo de datos boolean Bastidor RACK-PLC-01 Ranura 4 Canal 11 Dirección Q7.3 Mínimo de ingeniería 0.000000 Máximo de ingeniería 1.000000 Unidad state Mínimo bruto 0.000000 Máximo bruto 1.000000 Estado normal 0 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta DI-061
⌄
Detalles publicados Etiqueta DI-061 Descripción Sample line DI point 061 with function, scaling, and safe state recorded Dirección Entrada Tipo de señal Entrada digital Tipo de datos boolean Bastidor RACK-PLC-01 Ranura 4 Canal 12 Dirección I7.4 Mínimo de ingeniería 0.000000 Máximo de ingeniería 1.000000 Unidad state Mínimo bruto 0.000000 Máximo bruto 1.000000 Estado normal 0 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta DO-062
⌄
Detalles publicados Etiqueta DO-062 Descripción Sample line DO point 062 with function, scaling, and safe state recorded Dirección Salida Tipo de señal Salida digital Tipo de datos boolean Bastidor RACK-PLC-01 Ranura 4 Canal 13 Dirección Q7.5 Mínimo de ingeniería 0.000000 Máximo de ingeniería 1.000000 Unidad state Mínimo bruto 0.000000 Máximo bruto 1.000000 Estado normal 0 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta AI-063
⌄
Detalles publicados Etiqueta AI-063 Descripción Sample line AI point 063 with function, scaling, and safe state recorded Dirección Entrada Tipo de señal Entrada analógica Tipo de datos real Bastidor RACK-PLC-01 Ranura 4 Canal 14 Dirección IW188 Mínimo de ingeniería 0.000000 Máximo de ingeniería 100.000000 Unidad % Mínimo bruto 0.000000 Máximo bruto 27648.000000 Estado normal 50 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta AO-064
⌄
Detalles publicados Etiqueta AO-064 Descripción Sample line AO point 064 with function, scaling, and safe state recorded Dirección Salida Tipo de señal Salida analógica Tipo de datos real Bastidor RACK-PLC-01 Ranura 4 Canal 15 Dirección QW190 Mínimo de ingeniería 0.000000 Máximo de ingeniería 100.000000 Unidad % Mínimo bruto 0.000000 Máximo bruto 27648.000000 Estado normal 50 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta RTD-065
⌄
Detalles publicados Etiqueta RTD-065 Descripción Sample line RTD point 065 with function, scaling, and safe state recorded Dirección Entrada Tipo de señal rtd Tipo de datos real Bastidor RACK-PLC-01 Ranura 5 Canal 0 Dirección IW192 Mínimo de ingeniería 0.000000 Máximo de ingeniería 100.000000 Unidad °C Mínimo bruto 0.000000 Máximo bruto 27648.000000 Estado normal 50 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta PULSE-066
⌄
Detalles publicados Etiqueta PULSE-066 Descripción Sample line PULSE point 066 with function, scaling, and safe state recorded Dirección Salida Tipo de señal pulse Tipo de datos boolean Bastidor RACK-PLC-01 Ranura 5 Canal 1 Dirección Q8.1 Mínimo de ingeniería 0.000000 Máximo de ingeniería 1.000000 Unidad state Mínimo bruto 0.000000 Máximo bruto 1.000000 Estado normal 0 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta DI-067
⌄
Detalles publicados Etiqueta DI-067 Descripción Sample line DI point 067 with function, scaling, and safe state recorded Dirección Entrada Tipo de señal Entrada digital Tipo de datos boolean Bastidor RACK-PLC-01 Ranura 5 Canal 2 Dirección I8.2 Mínimo de ingeniería 0.000000 Máximo de ingeniería 1.000000 Unidad state Mínimo bruto 0.000000 Máximo bruto 1.000000 Estado normal 0 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta DO-068
⌄
Detalles publicados Etiqueta DO-068 Descripción Sample line DO point 068 with function, scaling, and safe state recorded Dirección Salida Tipo de señal Salida digital Tipo de datos boolean Bastidor RACK-PLC-01 Ranura 5 Canal 3 Dirección Q8.3 Mínimo de ingeniería 0.000000 Máximo de ingeniería 1.000000 Unidad state Mínimo bruto 0.000000 Máximo bruto 1.000000 Estado normal 0 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta AI-069
⌄
Detalles publicados Etiqueta AI-069 Descripción Sample line AI point 069 with function, scaling, and safe state recorded Dirección Entrada Tipo de señal Entrada analógica Tipo de datos real Bastidor RACK-PLC-01 Ranura 5 Canal 4 Dirección IW200 Mínimo de ingeniería 0.000000 Máximo de ingeniería 100.000000 Unidad % Mínimo bruto 0.000000 Máximo bruto 27648.000000 Estado normal 50 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta AO-070
⌄
Detalles publicados Etiqueta AO-070 Descripción Sample line AO point 070 with function, scaling, and safe state recorded Dirección Salida Tipo de señal Salida analógica Tipo de datos real Bastidor RACK-PLC-01 Ranura 5 Canal 5 Dirección QW202 Mínimo de ingeniería 0.000000 Máximo de ingeniería 100.000000 Unidad % Mínimo bruto 0.000000 Máximo bruto 27648.000000 Estado normal 50 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta RTD-071
⌄
Detalles publicados Etiqueta RTD-071 Descripción Sample line RTD point 071 with function, scaling, and safe state recorded Dirección Entrada Tipo de señal rtd Tipo de datos real Bastidor RACK-PLC-01 Ranura 5 Canal 6 Dirección IW204 Mínimo de ingeniería 0.000000 Máximo de ingeniería 100.000000 Unidad °C Mínimo bruto 0.000000 Máximo bruto 27648.000000 Estado normal 50 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta PULSE-072
⌄
Detalles publicados Etiqueta PULSE-072 Descripción Sample line PULSE point 072 with function, scaling, and safe state recorded Dirección Salida Tipo de señal pulse Tipo de datos boolean Bastidor RACK-PLC-01 Ranura 5 Canal 7 Dirección Q8.7 Mínimo de ingeniería 0.000000 Máximo de ingeniería 1.000000 Unidad state Mínimo bruto 0.000000 Máximo bruto 1.000000 Estado normal 0 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta DI-073
⌄
Detalles publicados Etiqueta DI-073 Descripción Sample line DI point 073 with function, scaling, and safe state recorded Dirección Entrada Tipo de señal Entrada digital Tipo de datos boolean Bastidor RACK-PLC-01 Ranura 5 Canal 8 Dirección I9.0 Mínimo de ingeniería 0.000000 Máximo de ingeniería 1.000000 Unidad state Mínimo bruto 0.000000 Máximo bruto 1.000000 Estado normal 0 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta DO-074
⌄
Detalles publicados Etiqueta DO-074 Descripción Sample line DO point 074 with function, scaling, and safe state recorded Dirección Salida Tipo de señal Salida digital Tipo de datos boolean Bastidor RACK-PLC-01 Ranura 5 Canal 9 Dirección Q9.1 Mínimo de ingeniería 0.000000 Máximo de ingeniería 1.000000 Unidad state Mínimo bruto 0.000000 Máximo bruto 1.000000 Estado normal 0 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta AI-075
⌄
Detalles publicados Etiqueta AI-075 Descripción Sample line AI point 075 with function, scaling, and safe state recorded Dirección Entrada Tipo de señal Entrada analógica Tipo de datos real Bastidor RACK-PLC-01 Ranura 5 Canal 10 Dirección IW212 Mínimo de ingeniería 0.000000 Máximo de ingeniería 100.000000 Unidad % Mínimo bruto 0.000000 Máximo bruto 27648.000000 Estado normal 50 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta AO-076
⌄
Detalles publicados Etiqueta AO-076 Descripción Sample line AO point 076 with function, scaling, and safe state recorded Dirección Salida Tipo de señal Salida analógica Tipo de datos real Bastidor RACK-PLC-01 Ranura 5 Canal 11 Dirección QW214 Mínimo de ingeniería 0.000000 Máximo de ingeniería 100.000000 Unidad % Mínimo bruto 0.000000 Máximo bruto 27648.000000 Estado normal 50 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta RTD-077
⌄
Detalles publicados Etiqueta RTD-077 Descripción Sample line RTD point 077 with function, scaling, and safe state recorded Dirección Entrada Tipo de señal rtd Tipo de datos real Bastidor RACK-PLC-01 Ranura 5 Canal 12 Dirección IW216 Mínimo de ingeniería 0.000000 Máximo de ingeniería 100.000000 Unidad °C Mínimo bruto 0.000000 Máximo bruto 27648.000000 Estado normal 50 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta PULSE-078
⌄
Detalles publicados Etiqueta PULSE-078 Descripción Sample line PULSE point 078 with function, scaling, and safe state recorded Dirección Salida Tipo de señal pulse Tipo de datos boolean Bastidor RACK-PLC-01 Ranura 5 Canal 13 Dirección Q9.5 Mínimo de ingeniería 0.000000 Máximo de ingeniería 1.000000 Unidad state Mínimo bruto 0.000000 Máximo bruto 1.000000 Estado normal 0 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta DI-079
⌄
Detalles publicados Etiqueta DI-079 Descripción Sample line DI point 079 with function, scaling, and safe state recorded Dirección Entrada Tipo de señal Entrada digital Tipo de datos boolean Bastidor RACK-PLC-01 Ranura 5 Canal 14 Dirección I9.6 Mínimo de ingeniería 0.000000 Máximo de ingeniería 1.000000 Unidad state Mínimo bruto 0.000000 Máximo bruto 1.000000 Estado normal 0 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta DO-080
⌄
Detalles publicados Etiqueta DO-080 Descripción Sample line DO point 080 with function, scaling, and safe state recorded Dirección Salida Tipo de señal Salida digital Tipo de datos boolean Bastidor RACK-PLC-01 Ranura 5 Canal 15 Dirección Q9.7 Mínimo de ingeniería 0.000000 Máximo de ingeniería 1.000000 Unidad state Mínimo bruto 0.000000 Máximo bruto 1.000000 Estado normal 0 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta AI-081
⌄
Detalles publicados Etiqueta AI-081 Descripción Sample line AI point 081 with function, scaling, and safe state recorded Dirección Entrada Tipo de señal Entrada analógica Tipo de datos real Bastidor RACK-RIO-01 Ranura 6 Canal 0 Dirección IW224 Mínimo de ingeniería 0.000000 Máximo de ingeniería 100.000000 Unidad % Mínimo bruto 0.000000 Máximo bruto 27648.000000 Estado normal 50 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta AO-082
⌄
Detalles publicados Etiqueta AO-082 Descripción Sample line AO point 082 with function, scaling, and safe state recorded Dirección Salida Tipo de señal Salida analógica Tipo de datos real Bastidor RACK-RIO-01 Ranura 6 Canal 1 Dirección QW226 Mínimo de ingeniería 0.000000 Máximo de ingeniería 100.000000 Unidad % Mínimo bruto 0.000000 Máximo bruto 27648.000000 Estado normal 50 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta RTD-083
⌄
Detalles publicados Etiqueta RTD-083 Descripción Sample line RTD point 083 with function, scaling, and safe state recorded Dirección Entrada Tipo de señal rtd Tipo de datos real Bastidor RACK-RIO-01 Ranura 6 Canal 2 Dirección IW228 Mínimo de ingeniería 0.000000 Máximo de ingeniería 100.000000 Unidad °C Mínimo bruto 0.000000 Máximo bruto 27648.000000 Estado normal 50 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta PULSE-084
⌄
Detalles publicados Etiqueta PULSE-084 Descripción Sample line PULSE point 084 with function, scaling, and safe state recorded Dirección Salida Tipo de señal pulse Tipo de datos boolean Bastidor RACK-RIO-01 Ranura 6 Canal 3 Dirección Q10.3 Mínimo de ingeniería 0.000000 Máximo de ingeniería 1.000000 Unidad state Mínimo bruto 0.000000 Máximo bruto 1.000000 Estado normal 0 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta DI-085
⌄
Detalles publicados Etiqueta DI-085 Descripción Sample line DI point 085 with function, scaling, and safe state recorded Dirección Entrada Tipo de señal Entrada digital Tipo de datos boolean Bastidor RACK-RIO-01 Ranura 6 Canal 4 Dirección I10.4 Mínimo de ingeniería 0.000000 Máximo de ingeniería 1.000000 Unidad state Mínimo bruto 0.000000 Máximo bruto 1.000000 Estado normal 0 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta DO-086
⌄
Detalles publicados Etiqueta DO-086 Descripción Sample line DO point 086 with function, scaling, and safe state recorded Dirección Salida Tipo de señal Salida digital Tipo de datos boolean Bastidor RACK-RIO-01 Ranura 6 Canal 5 Dirección Q10.5 Mínimo de ingeniería 0.000000 Máximo de ingeniería 1.000000 Unidad state Mínimo bruto 0.000000 Máximo bruto 1.000000 Estado normal 0 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta AI-087
⌄
Detalles publicados Etiqueta AI-087 Descripción Sample line AI point 087 with function, scaling, and safe state recorded Dirección Entrada Tipo de señal Entrada analógica Tipo de datos real Bastidor RACK-RIO-01 Ranura 6 Canal 6 Dirección IW236 Mínimo de ingeniería 0.000000 Máximo de ingeniería 100.000000 Unidad % Mínimo bruto 0.000000 Máximo bruto 27648.000000 Estado normal 50 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta AO-088
⌄
Detalles publicados Etiqueta AO-088 Descripción Sample line AO point 088 with function, scaling, and safe state recorded Dirección Salida Tipo de señal Salida analógica Tipo de datos real Bastidor RACK-RIO-01 Ranura 6 Canal 7 Dirección QW238 Mínimo de ingeniería 0.000000 Máximo de ingeniería 100.000000 Unidad % Mínimo bruto 0.000000 Máximo bruto 27648.000000 Estado normal 50 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta RTD-089
⌄
Detalles publicados Etiqueta RTD-089 Descripción Sample line RTD point 089 with function, scaling, and safe state recorded Dirección Entrada Tipo de señal rtd Tipo de datos real Bastidor RACK-RIO-01 Ranura 6 Canal 8 Dirección IW240 Mínimo de ingeniería 0.000000 Máximo de ingeniería 100.000000 Unidad °C Mínimo bruto 0.000000 Máximo bruto 27648.000000 Estado normal 50 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta PULSE-090
⌄
Detalles publicados Etiqueta PULSE-090 Descripción Sample line PULSE point 090 with function, scaling, and safe state recorded Dirección Salida Tipo de señal pulse Tipo de datos boolean Bastidor RACK-RIO-01 Ranura 6 Canal 9 Dirección Q11.1 Mínimo de ingeniería 0.000000 Máximo de ingeniería 1.000000 Unidad state Mínimo bruto 0.000000 Máximo bruto 1.000000 Estado normal 0 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta DI-091
⌄
Detalles publicados Etiqueta DI-091 Descripción Sample line DI point 091 with function, scaling, and safe state recorded Dirección Entrada Tipo de señal Entrada digital Tipo de datos boolean Bastidor RACK-RIO-01 Ranura 6 Canal 10 Dirección I11.2 Mínimo de ingeniería 0.000000 Máximo de ingeniería 1.000000 Unidad state Mínimo bruto 0.000000 Máximo bruto 1.000000 Estado normal 0 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta DO-092
⌄
Detalles publicados Etiqueta DO-092 Descripción Sample line DO point 092 with function, scaling, and safe state recorded Dirección Salida Tipo de señal Salida digital Tipo de datos boolean Bastidor RACK-RIO-01 Ranura 6 Canal 11 Dirección Q11.3 Mínimo de ingeniería 0.000000 Máximo de ingeniería 1.000000 Unidad state Mínimo bruto 0.000000 Máximo bruto 1.000000 Estado normal 0 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta AI-093
⌄
Detalles publicados Etiqueta AI-093 Descripción Sample line AI point 093 with function, scaling, and safe state recorded Dirección Entrada Tipo de señal Entrada analógica Tipo de datos real Bastidor RACK-RIO-01 Ranura 6 Canal 12 Dirección IW248 Mínimo de ingeniería 0.000000 Máximo de ingeniería 100.000000 Unidad % Mínimo bruto 0.000000 Máximo bruto 27648.000000 Estado normal 50 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta AO-094
⌄
Detalles publicados Etiqueta AO-094 Descripción Sample line AO point 094 with function, scaling, and safe state recorded Dirección Salida Tipo de señal Salida analógica Tipo de datos real Bastidor RACK-RIO-01 Ranura 6 Canal 13 Dirección QW250 Mínimo de ingeniería 0.000000 Máximo de ingeniería 100.000000 Unidad % Mínimo bruto 0.000000 Máximo bruto 27648.000000 Estado normal 50 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta RTD-095
⌄
Detalles publicados Etiqueta RTD-095 Descripción Sample line RTD point 095 with function, scaling, and safe state recorded Dirección Entrada Tipo de señal rtd Tipo de datos real Bastidor RACK-RIO-01 Ranura 6 Canal 14 Dirección IW252 Mínimo de ingeniería 0.000000 Máximo de ingeniería 100.000000 Unidad °C Mínimo bruto 0.000000 Máximo bruto 27648.000000 Estado normal 50 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta PULSE-096
⌄
Detalles publicados Etiqueta PULSE-096 Descripción Sample line PULSE point 096 with function, scaling, and safe state recorded Dirección Salida Tipo de señal pulse Tipo de datos boolean Bastidor RACK-RIO-01 Ranura 6 Canal 15 Dirección Q11.7 Mínimo de ingeniería 0.000000 Máximo de ingeniería 1.000000 Unidad state Mínimo bruto 0.000000 Máximo bruto 1.000000 Estado normal 0 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel MCC-01 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta DI-097
⌄
Detalles publicados Etiqueta DI-097 Descripción Sample line DI point 097 with function, scaling, and safe state recorded Dirección Entrada Tipo de señal Entrada digital Tipo de datos boolean Bastidor RACK-RIO-01 Ranura 7 Canal 0 Dirección I12.0 Mínimo de ingeniería 0.000000 Máximo de ingeniería 1.000000 Unidad state Mínimo bruto 0.000000 Máximo bruto 1.000000 Estado normal 0 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel RIO-101 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta DO-098
⌄
Detalles publicados Etiqueta DO-098 Descripción Sample line DO point 098 with function, scaling, and safe state recorded Dirección Salida Tipo de señal Salida digital Tipo de datos boolean Bastidor RACK-RIO-01 Ranura 7 Canal 1 Dirección Q12.1 Mínimo de ingeniería 0.000000 Máximo de ingeniería 1.000000 Unidad state Mínimo bruto 0.000000 Máximo bruto 1.000000 Estado normal 0 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel RIO-101 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta AI-099
⌄
Detalles publicados Etiqueta AI-099 Descripción Sample line AI point 099 with function, scaling, and safe state recorded Dirección Entrada Tipo de señal Entrada analógica Tipo de datos real Bastidor RACK-RIO-01 Ranura 7 Canal 2 Dirección IW260 Mínimo de ingeniería 0.000000 Máximo de ingeniería 100.000000 Unidad % Mínimo bruto 0.000000 Máximo bruto 27648.000000 Estado normal 50 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel RIO-101 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta AO-100
⌄
Detalles publicados Etiqueta AO-100 Descripción Sample line AO point 100 with function, scaling, and safe state recorded Dirección Salida Tipo de señal Salida analógica Tipo de datos real Bastidor RACK-RIO-01 Ranura 7 Canal 3 Dirección QW262 Mínimo de ingeniería 0.000000 Máximo de ingeniería 100.000000 Unidad % Mínimo bruto 0.000000 Máximo bruto 27648.000000 Estado normal 50 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel RIO-101 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta RTD-101
⌄
Detalles publicados Etiqueta RTD-101 Descripción Sample line RTD point 101 with function, scaling, and safe state recorded Dirección Entrada Tipo de señal rtd Tipo de datos real Bastidor RACK-RIO-01 Ranura 7 Canal 4 Dirección IW264 Mínimo de ingeniería 0.000000 Máximo de ingeniería 100.000000 Unidad °C Mínimo bruto 0.000000 Máximo bruto 27648.000000 Estado normal 50 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel RIO-101 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta PULSE-102
⌄
Detalles publicados Etiqueta PULSE-102 Descripción Sample line PULSE point 102 with function, scaling, and safe state recorded Dirección Salida Tipo de señal pulse Tipo de datos boolean Bastidor RACK-RIO-01 Ranura 7 Canal 5 Dirección Q12.5 Mínimo de ingeniería 0.000000 Máximo de ingeniería 1.000000 Unidad state Mínimo bruto 0.000000 Máximo bruto 1.000000 Estado normal 0 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel RIO-101 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta DI-103
⌄
Detalles publicados Etiqueta DI-103 Descripción Sample line DI point 103 with function, scaling, and safe state recorded Dirección Entrada Tipo de señal Entrada digital Tipo de datos boolean Bastidor RACK-RIO-01 Ranura 7 Canal 6 Dirección I12.6 Mínimo de ingeniería 0.000000 Máximo de ingeniería 1.000000 Unidad state Mínimo bruto 0.000000 Máximo bruto 1.000000 Estado normal 0 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel RIO-101 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta DO-104
⌄
Detalles publicados Etiqueta DO-104 Descripción Sample line DO point 104 with function, scaling, and safe state recorded Dirección Salida Tipo de señal Salida digital Tipo de datos boolean Bastidor RACK-RIO-01 Ranura 7 Canal 7 Dirección Q12.7 Mínimo de ingeniería 0.000000 Máximo de ingeniería 1.000000 Unidad state Mínimo bruto 0.000000 Máximo bruto 1.000000 Estado normal 0 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel RIO-101 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta AI-105
⌄
Detalles publicados Etiqueta AI-105 Descripción Sample line AI point 105 with function, scaling, and safe state recorded Dirección Entrada Tipo de señal Entrada analógica Tipo de datos real Bastidor RACK-RIO-01 Ranura 7 Canal 8 Dirección IW272 Mínimo de ingeniería 0.000000 Máximo de ingeniería 100.000000 Unidad % Mínimo bruto 0.000000 Máximo bruto 27648.000000 Estado normal 50 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel RIO-101 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta AO-106
⌄
Detalles publicados Etiqueta AO-106 Descripción Sample line AO point 106 with function, scaling, and safe state recorded Dirección Salida Tipo de señal Salida analógica Tipo de datos real Bastidor RACK-RIO-01 Ranura 7 Canal 9 Dirección QW274 Mínimo de ingeniería 0.000000 Máximo de ingeniería 100.000000 Unidad % Mínimo bruto 0.000000 Máximo bruto 27648.000000 Estado normal 50 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel RIO-101 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta RTD-107
⌄
Detalles publicados Etiqueta RTD-107 Descripción Sample line RTD point 107 with function, scaling, and safe state recorded Dirección Entrada Tipo de señal rtd Tipo de datos real Bastidor RACK-RIO-01 Ranura 7 Canal 10 Dirección IW276 Mínimo de ingeniería 0.000000 Máximo de ingeniería 100.000000 Unidad °C Mínimo bruto 0.000000 Máximo bruto 27648.000000 Estado normal 50 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel RIO-101 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta PULSE-108
⌄
Detalles publicados Etiqueta PULSE-108 Descripción Sample line PULSE point 108 with function, scaling, and safe state recorded Dirección Salida Tipo de señal pulse Tipo de datos boolean Bastidor RACK-RIO-01 Ranura 7 Canal 11 Dirección Q13.3 Mínimo de ingeniería 0.000000 Máximo de ingeniería 1.000000 Unidad state Mínimo bruto 0.000000 Máximo bruto 1.000000 Estado normal 0 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel RIO-101 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta DI-109
⌄
Detalles publicados Etiqueta DI-109 Descripción Sample line DI point 109 with function, scaling, and safe state recorded Dirección Entrada Tipo de señal Entrada digital Tipo de datos boolean Bastidor RACK-RIO-01 Ranura 7 Canal 12 Dirección I13.4 Mínimo de ingeniería 0.000000 Máximo de ingeniería 1.000000 Unidad state Mínimo bruto 0.000000 Máximo bruto 1.000000 Estado normal 0 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel RIO-101 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta DO-110
⌄
Detalles publicados Etiqueta DO-110 Descripción Sample line DO point 110 with function, scaling, and safe state recorded Dirección Salida Tipo de señal Salida digital Tipo de datos boolean Bastidor RACK-RIO-01 Ranura 7 Canal 13 Dirección Q13.5 Mínimo de ingeniería 0.000000 Máximo de ingeniería 1.000000 Unidad state Mínimo bruto 0.000000 Máximo bruto 1.000000 Estado normal 0 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel RIO-101 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta AI-111
⌄
Detalles publicados Etiqueta AI-111 Descripción Sample line AI point 111 with function, scaling, and safe state recorded Dirección Entrada Tipo de señal Entrada analógica Tipo de datos real Bastidor RACK-RIO-01 Ranura 7 Canal 14 Dirección IW284 Mínimo de ingeniería 0.000000 Máximo de ingeniería 100.000000 Unidad % Mínimo bruto 0.000000 Máximo bruto 27648.000000 Estado normal 50 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel RIO-101 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta AO-112
⌄
Detalles publicados Etiqueta AO-112 Descripción Sample line AO point 112 with function, scaling, and safe state recorded Dirección Salida Tipo de señal Salida analógica Tipo de datos real Bastidor RACK-RIO-01 Ranura 7 Canal 15 Dirección QW286 Mínimo de ingeniería 0.000000 Máximo de ingeniería 100.000000 Unidad % Mínimo bruto 0.000000 Máximo bruto 27648.000000 Estado normal 50 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel RIO-101 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta RTD-113
⌄
Detalles publicados Etiqueta RTD-113 Descripción Sample line RTD point 113 with function, scaling, and safe state recorded Dirección Entrada Tipo de señal rtd Tipo de datos real Bastidor RACK-RIO-01 Ranura 8 Canal 0 Dirección IW288 Mínimo de ingeniería 0.000000 Máximo de ingeniería 100.000000 Unidad °C Mínimo bruto 0.000000 Máximo bruto 27648.000000 Estado normal 50 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel RIO-101 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta PULSE-114
⌄
Detalles publicados Etiqueta PULSE-114 Descripción Sample line PULSE point 114 with function, scaling, and safe state recorded Dirección Salida Tipo de señal pulse Tipo de datos boolean Bastidor RACK-RIO-01 Ranura 8 Canal 1 Dirección Q14.1 Mínimo de ingeniería 0.000000 Máximo de ingeniería 1.000000 Unidad state Mínimo bruto 0.000000 Máximo bruto 1.000000 Estado normal 0 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel RIO-101 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta DI-115
⌄
Detalles publicados Etiqueta DI-115 Descripción Sample line DI point 115 with function, scaling, and safe state recorded Dirección Entrada Tipo de señal Entrada digital Tipo de datos boolean Bastidor RACK-RIO-01 Ranura 8 Canal 2 Dirección I14.2 Mínimo de ingeniería 0.000000 Máximo de ingeniería 1.000000 Unidad state Mínimo bruto 0.000000 Máximo bruto 1.000000 Estado normal 0 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel RIO-101 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta DO-116
⌄
Detalles publicados Etiqueta DO-116 Descripción Sample line DO point 116 with function, scaling, and safe state recorded Dirección Salida Tipo de señal Salida digital Tipo de datos boolean Bastidor RACK-RIO-01 Ranura 8 Canal 3 Dirección Q14.3 Mínimo de ingeniería 0.000000 Máximo de ingeniería 1.000000 Unidad state Mínimo bruto 0.000000 Máximo bruto 1.000000 Estado normal 0 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel RIO-101 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta AI-117
⌄
Detalles publicados Etiqueta AI-117 Descripción Sample line AI point 117 with function, scaling, and safe state recorded Dirección Entrada Tipo de señal Entrada analógica Tipo de datos real Bastidor RACK-RIO-01 Ranura 8 Canal 4 Dirección IW296 Mínimo de ingeniería 0.000000 Máximo de ingeniería 100.000000 Unidad % Mínimo bruto 0.000000 Máximo bruto 27648.000000 Estado normal 50 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel RIO-101 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta AO-118
⌄
Detalles publicados Etiqueta AO-118 Descripción Sample line AO point 118 with function, scaling, and safe state recorded Dirección Salida Tipo de señal Salida analógica Tipo de datos real Bastidor RACK-RIO-01 Ranura 8 Canal 5 Dirección QW298 Mínimo de ingeniería 0.000000 Máximo de ingeniería 100.000000 Unidad % Mínimo bruto 0.000000 Máximo bruto 27648.000000 Estado normal 50 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel RIO-101 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta RTD-119
⌄
Detalles publicados Etiqueta RTD-119 Descripción Sample line RTD point 119 with function, scaling, and safe state recorded Dirección Entrada Tipo de señal rtd Tipo de datos real Bastidor RACK-RIO-01 Ranura 8 Canal 6 Dirección IW300 Mínimo de ingeniería 0.000000 Máximo de ingeniería 100.000000 Unidad °C Mínimo bruto 0.000000 Máximo bruto 27648.000000 Estado normal 50 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel RIO-101 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta PULSE-120
⌄
Detalles publicados Etiqueta PULSE-120 Descripción Sample line PULSE point 120 with function, scaling, and safe state recorded Dirección Salida Tipo de señal pulse Tipo de datos boolean Bastidor RACK-RIO-01 Ranura 8 Canal 7 Dirección Q14.7 Mínimo de ingeniería 0.000000 Máximo de ingeniería 1.000000 Unidad state Mínimo bruto 0.000000 Máximo bruto 1.000000 Estado normal 0 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel RIO-101 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta DI-121
⌄
Detalles publicados Etiqueta DI-121 Descripción Sample line DI point 121 with function, scaling, and safe state recorded Dirección Entrada Tipo de señal Entrada digital Tipo de datos boolean Bastidor RACK-RIO-01 Ranura 8 Canal 8 Dirección I15.0 Mínimo de ingeniería 0.000000 Máximo de ingeniería 1.000000 Unidad state Mínimo bruto 0.000000 Máximo bruto 1.000000 Estado normal 0 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel RIO-101 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta DO-122
⌄
Detalles publicados Etiqueta DO-122 Descripción Sample line DO point 122 with function, scaling, and safe state recorded Dirección Salida Tipo de señal Salida digital Tipo de datos boolean Bastidor RACK-RIO-01 Ranura 8 Canal 9 Dirección Q15.1 Mínimo de ingeniería 0.000000 Máximo de ingeniería 1.000000 Unidad state Mínimo bruto 0.000000 Máximo bruto 1.000000 Estado normal 0 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel RIO-101 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta AI-123
⌄
Detalles publicados Etiqueta AI-123 Descripción Sample line AI point 123 with function, scaling, and safe state recorded Dirección Entrada Tipo de señal Entrada analógica Tipo de datos real Bastidor RACK-RIO-01 Ranura 8 Canal 10 Dirección IW308 Mínimo de ingeniería 0.000000 Máximo de ingeniería 100.000000 Unidad % Mínimo bruto 0.000000 Máximo bruto 27648.000000 Estado normal 50 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel RIO-101 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta AO-124
⌄
Detalles publicados Etiqueta AO-124 Descripción Sample line AO point 124 with function, scaling, and safe state recorded Dirección Salida Tipo de señal Salida analógica Tipo de datos real Bastidor RACK-RIO-01 Ranura 8 Canal 11 Dirección QW310 Mínimo de ingeniería 0.000000 Máximo de ingeniería 100.000000 Unidad % Mínimo bruto 0.000000 Máximo bruto 27648.000000 Estado normal 50 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel RIO-101 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta RTD-125
⌄
Detalles publicados Etiqueta RTD-125 Descripción Sample line RTD point 125 with function, scaling, and safe state recorded Dirección Entrada Tipo de señal rtd Tipo de datos real Bastidor RACK-RIO-01 Ranura 8 Canal 12 Dirección IW312 Mínimo de ingeniería 0.000000 Máximo de ingeniería 100.000000 Unidad °C Mínimo bruto 0.000000 Máximo bruto 27648.000000 Estado normal 50 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel RIO-101 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta PULSE-126
⌄
Detalles publicados Etiqueta PULSE-126 Descripción Sample line PULSE point 126 with function, scaling, and safe state recorded Dirección Salida Tipo de señal pulse Tipo de datos boolean Bastidor RACK-RIO-01 Ranura 8 Canal 13 Dirección Q15.5 Mínimo de ingeniería 0.000000 Máximo de ingeniería 1.000000 Unidad state Mínimo bruto 0.000000 Máximo bruto 1.000000 Estado normal 0 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel RIO-101 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta DI-127
⌄
Detalles publicados Etiqueta DI-127 Descripción Sample line DI point 127 with function, scaling, and safe state recorded Dirección Entrada Tipo de señal Entrada digital Tipo de datos boolean Bastidor RACK-RIO-01 Ranura 8 Canal 14 Dirección I15.6 Mínimo de ingeniería 0.000000 Máximo de ingeniería 1.000000 Unidad state Mínimo bruto 0.000000 Máximo bruto 1.000000 Estado normal 0 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel RIO-101 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta DO-128
⌄
Detalles publicados Etiqueta DO-128 Descripción Sample line DO point 128 with function, scaling, and safe state recorded Dirección Salida Tipo de señal Salida digital Tipo de datos boolean Bastidor RACK-RIO-01 Ranura 8 Canal 15 Dirección Q15.7 Mínimo de ingeniería 0.000000 Máximo de ingeniería 1.000000 Unidad state Mínimo bruto 0.000000 Máximo bruto 1.000000 Estado normal 0 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel RIO-101 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta AI-129
⌄
Detalles publicados Etiqueta AI-129 Descripción Sample line AI point 129 with function, scaling, and safe state recorded Dirección Entrada Tipo de señal Entrada analógica Tipo de datos real Bastidor RACK-RIO-01 Ranura 9 Canal 0 Dirección IW320 Mínimo de ingeniería 0.000000 Máximo de ingeniería 100.000000 Unidad % Mínimo bruto 0.000000 Máximo bruto 27648.000000 Estado normal 50 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel RIO-101 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta AO-130
⌄
Detalles publicados Etiqueta AO-130 Descripción Sample line AO point 130 with function, scaling, and safe state recorded Dirección Salida Tipo de señal Salida analógica Tipo de datos real Bastidor RACK-RIO-01 Ranura 9 Canal 1 Dirección QW322 Mínimo de ingeniería 0.000000 Máximo de ingeniería 100.000000 Unidad % Mínimo bruto 0.000000 Máximo bruto 27648.000000 Estado normal 50 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel RIO-101 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta RTD-131
⌄
Detalles publicados Etiqueta RTD-131 Descripción Sample line RTD point 131 with function, scaling, and safe state recorded Dirección Entrada Tipo de señal rtd Tipo de datos real Bastidor RACK-RIO-01 Ranura 9 Canal 2 Dirección IW324 Mínimo de ingeniería 0.000000 Máximo de ingeniería 100.000000 Unidad °C Mínimo bruto 0.000000 Máximo bruto 27648.000000 Estado normal 50 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel RIO-101 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta PULSE-132
⌄
Detalles publicados Etiqueta PULSE-132 Descripción Sample line PULSE point 132 with function, scaling, and safe state recorded Dirección Salida Tipo de señal pulse Tipo de datos boolean Bastidor RACK-RIO-01 Ranura 9 Canal 3 Dirección Q16.3 Mínimo de ingeniería 0.000000 Máximo de ingeniería 1.000000 Unidad state Mínimo bruto 0.000000 Máximo bruto 1.000000 Estado normal 0 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel RIO-101 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta DI-133
⌄
Detalles publicados Etiqueta DI-133 Descripción Sample line DI point 133 with function, scaling, and safe state recorded Dirección Entrada Tipo de señal Entrada digital Tipo de datos boolean Bastidor RACK-RIO-01 Ranura 9 Canal 4 Dirección I16.4 Mínimo de ingeniería 0.000000 Máximo de ingeniería 1.000000 Unidad state Mínimo bruto 0.000000 Máximo bruto 1.000000 Estado normal 0 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel RIO-101 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta DO-134
⌄
Detalles publicados Etiqueta DO-134 Descripción Sample line DO point 134 with function, scaling, and safe state recorded Dirección Salida Tipo de señal Salida digital Tipo de datos boolean Bastidor RACK-RIO-01 Ranura 9 Canal 5 Dirección Q16.5 Mínimo de ingeniería 0.000000 Máximo de ingeniería 1.000000 Unidad state Mínimo bruto 0.000000 Máximo bruto 1.000000 Estado normal 0 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel RIO-101 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta AI-135
⌄
Detalles publicados Etiqueta AI-135 Descripción Sample line AI point 135 with function, scaling, and safe state recorded Dirección Entrada Tipo de señal Entrada analógica Tipo de datos real Bastidor RACK-RIO-01 Ranura 9 Canal 6 Dirección IW332 Mínimo de ingeniería 0.000000 Máximo de ingeniería 100.000000 Unidad % Mínimo bruto 0.000000 Máximo bruto 27648.000000 Estado normal 50 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel RIO-101 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta AO-136
⌄
Detalles publicados Etiqueta AO-136 Descripción Sample line AO point 136 with function, scaling, and safe state recorded Dirección Salida Tipo de señal Salida analógica Tipo de datos real Bastidor RACK-RIO-01 Ranura 9 Canal 7 Dirección QW334 Mínimo de ingeniería 0.000000 Máximo de ingeniería 100.000000 Unidad % Mínimo bruto 0.000000 Máximo bruto 27648.000000 Estado normal 50 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel RIO-101 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta RTD-137
⌄
Detalles publicados Etiqueta RTD-137 Descripción Sample line RTD point 137 with function, scaling, and safe state recorded Dirección Entrada Tipo de señal rtd Tipo de datos real Bastidor RACK-RIO-01 Ranura 9 Canal 8 Dirección IW336 Mínimo de ingeniería 0.000000 Máximo de ingeniería 100.000000 Unidad °C Mínimo bruto 0.000000 Máximo bruto 27648.000000 Estado normal 50 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel RIO-101 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta PULSE-138
⌄
Detalles publicados Etiqueta PULSE-138 Descripción Sample line PULSE point 138 with function, scaling, and safe state recorded Dirección Salida Tipo de señal pulse Tipo de datos boolean Bastidor RACK-RIO-01 Ranura 9 Canal 9 Dirección Q17.1 Mínimo de ingeniería 0.000000 Máximo de ingeniería 1.000000 Unidad state Mínimo bruto 0.000000 Máximo bruto 1.000000 Estado normal 0 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel RIO-101 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta DI-139
⌄
Detalles publicados Etiqueta DI-139 Descripción Sample line DI point 139 with function, scaling, and safe state recorded Dirección Entrada Tipo de señal Entrada digital Tipo de datos boolean Bastidor RACK-RIO-01 Ranura 9 Canal 10 Dirección I17.2 Mínimo de ingeniería 0.000000 Máximo de ingeniería 1.000000 Unidad state Mínimo bruto 0.000000 Máximo bruto 1.000000 Estado normal 0 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel RIO-101 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta DO-140
⌄
Detalles publicados Etiqueta DO-140 Descripción Sample line DO point 140 with function, scaling, and safe state recorded Dirección Salida Tipo de señal Salida digital Tipo de datos boolean Bastidor RACK-RIO-01 Ranura 9 Canal 11 Dirección Q17.3 Mínimo de ingeniería 0.000000 Máximo de ingeniería 1.000000 Unidad state Mínimo bruto 0.000000 Máximo bruto 1.000000 Estado normal 0 Estado seguro 0 Reserva No Ubicación Packaging hall, line one Panel RIO-101 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta AI-141
⌄
Detalles publicados Etiqueta AI-141 Descripción Sample line AI point 141 with function, scaling, and safe state recorded Dirección Entrada Tipo de señal Entrada analógica Tipo de datos real Bastidor RACK-RIO-01 Ranura 9 Canal 12 Dirección IW344 Mínimo de ingeniería 0.000000 Máximo de ingeniería 100.000000 Unidad % Mínimo bruto 0.000000 Máximo bruto 27648.000000 Estado normal 50 Estado seguro 0 Reserva Sí Ubicación Packaging hall, line one Panel RIO-101 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta AO-142
⌄
Detalles publicados Etiqueta AO-142 Descripción Sample line AO point 142 with function, scaling, and safe state recorded Dirección Salida Tipo de señal Salida analógica Tipo de datos real Bastidor RACK-RIO-01 Ranura 9 Canal 13 Dirección QW346 Mínimo de ingeniería 0.000000 Máximo de ingeniería 100.000000 Unidad % Mínimo bruto 0.000000 Máximo bruto 27648.000000 Estado normal 50 Estado seguro 0 Reserva Sí Ubicación Packaging hall, line one Panel RIO-101 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta RTD-143
⌄
Detalles publicados Etiqueta RTD-143 Descripción Sample line RTD point 143 with function, scaling, and safe state recorded Dirección Entrada Tipo de señal rtd Tipo de datos real Bastidor RACK-RIO-01 Ranura 9 Canal 14 Dirección IW348 Mínimo de ingeniería 0.000000 Máximo de ingeniería 100.000000 Unidad °C Mínimo bruto 0.000000 Máximo bruto 27648.000000 Estado normal 50 Estado seguro 0 Reserva Sí Ubicación Packaging hall, line one Panel RIO-101 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta PULSE-144
⌄
Detalles publicados Etiqueta PULSE-144 Descripción Sample line PULSE point 144 with function, scaling, and safe state recorded Dirección Salida Tipo de señal pulse Tipo de datos boolean Bastidor RACK-RIO-01 Ranura 9 Canal 15 Dirección Q17.7 Mínimo de ingeniería 0.000000 Máximo de ingeniería 1.000000 Unidad state Mínimo bruto 0.000000 Máximo bruto 1.000000 Estado normal 0 Estado seguro 0 Reserva Sí Ubicación Packaging hall, line one Panel RIO-101 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta DI-145
⌄
Detalles publicados Etiqueta DI-145 Descripción Sample line DI point 145 with function, scaling, and safe state recorded Dirección Entrada Tipo de señal Entrada digital Tipo de datos boolean Bastidor RACK-RIO-01 Ranura 10 Canal 0 Dirección I18.0 Mínimo de ingeniería 0.000000 Máximo de ingeniería 1.000000 Unidad state Mínimo bruto 0.000000 Máximo bruto 1.000000 Estado normal 0 Estado seguro 0 Reserva Sí Ubicación Packaging hall, line one Panel RIO-101 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta DO-146
⌄
Detalles publicados Etiqueta DO-146 Descripción Sample line DO point 146 with function, scaling, and safe state recorded Dirección Salida Tipo de señal Salida digital Tipo de datos boolean Bastidor RACK-RIO-01 Ranura 10 Canal 1 Dirección Q18.1 Mínimo de ingeniería 0.000000 Máximo de ingeniería 1.000000 Unidad state Mínimo bruto 0.000000 Máximo bruto 1.000000 Estado normal 0 Estado seguro 0 Reserva Sí Ubicación Packaging hall, line one Panel RIO-101 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta AI-147
⌄
Detalles publicados Etiqueta AI-147 Descripción Sample line AI point 147 with function, scaling, and safe state recorded Dirección Entrada Tipo de señal Entrada analógica Tipo de datos real Bastidor RACK-RIO-01 Ranura 10 Canal 2 Dirección IW356 Mínimo de ingeniería 0.000000 Máximo de ingeniería 100.000000 Unidad % Mínimo bruto 0.000000 Máximo bruto 27648.000000 Estado normal 50 Estado seguro 0 Reserva Sí Ubicación Packaging hall, line one Panel RIO-101 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta AO-148
⌄
Detalles publicados Etiqueta AO-148 Descripción Sample line AO point 148 with function, scaling, and safe state recorded Dirección Salida Tipo de señal Salida analógica Tipo de datos real Bastidor RACK-RIO-01 Ranura 10 Canal 3 Dirección QW358 Mínimo de ingeniería 0.000000 Máximo de ingeniería 100.000000 Unidad % Mínimo bruto 0.000000 Máximo bruto 27648.000000 Estado normal 50 Estado seguro 0 Reserva Sí Ubicación Packaging hall, line one Panel RIO-101 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta RTD-149
⌄
Detalles publicados Etiqueta RTD-149 Descripción Sample line RTD point 149 with function, scaling, and safe state recorded Dirección Entrada Tipo de señal rtd Tipo de datos real Bastidor RACK-RIO-01 Ranura 10 Canal 4 Dirección IW360 Mínimo de ingeniería 0.000000 Máximo de ingeniería 100.000000 Unidad °C Mínimo bruto 0.000000 Máximo bruto 27648.000000 Estado normal 50 Estado seguro 0 Reserva Sí Ubicación Packaging hall, line one Panel RIO-101 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Punto E/S
Punto E/S Activo Etiqueta PULSE-150
⌄
Detalles publicados Etiqueta PULSE-150 Descripción Sample line PULSE point 150 with function, scaling, and safe state recorded Dirección Salida Tipo de señal pulse Tipo de datos boolean Bastidor RACK-RIO-01 Ranura 10 Canal 5 Dirección Q18.5 Mínimo de ingeniería 0.000000 Máximo de ingeniería 1.000000 Unidad state Mínimo bruto 0.000000 Máximo bruto 1.000000 Estado normal 0 Estado seguro 0 Reserva Sí Ubicación Packaging hall, line one Panel RIO-101 Estado Activo Notas Terminal, cable, signal direction, engineering scale, and fail-safe logic were verified against the as-built drawing.
Dispositivo de red
7 ⌄
Dispositivo de red
Dispositivo de red Activo Nombre del dispositivo SW-CTRL-01 Modelo SCALANCE XC208 Dirección IP 192.168.10.2
⌄
Detalles publicados Nombre del dispositivo SW-CTRL-01 Tipo de dispositivo managed_switch Proveedor Siemens Modelo SCALANCE XC208 Medio de red industrial_ethernet Protocolo profinet Rol del protocolo supervisor Nombre PROFINET sw-ctrl-01 Dirección IP 192.168.10.2 Prefijo de subred 24 Máscara de subred 255.255.255.0 Puerta de enlace 192.168.10.1 VLAN 10 Puerto del switch Uplink-01 Dirección MAC AA:10:00:00:00:01 Ubicación Control network, packaging hall Estado Activo Notas Address, PROFINET name, VLAN, switch port, and MAC were verified against the network drawing and configuration backup.
Dispositivo de red
Dispositivo de red Activo Nombre del dispositivo PLC-101 Modelo S7-1515-2 PN Dirección IP 192.168.10.10
⌄
Detalles publicados Nombre del dispositivo PLC-101 Tipo de dispositivo controller Proveedor Siemens Modelo S7-1515-2 PN Medio de red industrial_ethernet Protocolo profinet Rol del protocolo controller Nombre PROFINET plc-101 Dirección IP 192.168.10.10 Prefijo de subred 24 Máscara de subred 255.255.255.0 Puerta de enlace 192.168.10.1 VLAN 10 Puerto del switch 1 Dirección MAC AA:10:00:00:00:02 Ubicación Control network, packaging hall Estado Activo Notas Address, PROFINET name, VLAN, switch port, and MAC were verified against the network drawing and configuration backup.
Dispositivo de red
Dispositivo de red Activo Nombre del dispositivo HMI-101 Modelo TP1200 Comfort Dirección IP 192.168.10.20
⌄
Detalles publicados Nombre del dispositivo HMI-101 Tipo de dispositivo hmi Proveedor Siemens Modelo TP1200 Comfort Medio de red industrial_ethernet Protocolo profinet Rol del protocolo device Nombre PROFINET hmi-101 Dirección IP 192.168.10.20 Prefijo de subred 24 Máscara de subred 255.255.255.0 Puerta de enlace 192.168.10.1 VLAN 10 Puerto del switch 2 Dirección MAC AA:10:00:00:00:03 Ubicación Control network, packaging hall Estado Activo Notas Address, PROFINET name, VLAN, switch port, and MAC were verified against the network drawing and configuration backup.
Dispositivo de red
Dispositivo de red Activo Nombre del dispositivo RIO-101 Modelo ET 200SP Dirección IP 192.168.10.30
⌄
Detalles publicados Nombre del dispositivo RIO-101 Tipo de dispositivo remote_io Proveedor Siemens Modelo ET 200SP Medio de red industrial_ethernet Protocolo profinet Rol del protocolo device Nombre PROFINET rio-101 Dirección IP 192.168.10.30 Prefijo de subred 24 Máscara de subred 255.255.255.0 Puerta de enlace 192.168.10.1 VLAN 10 Puerto del switch 3 Dirección MAC AA:10:00:00:00:04 Ubicación Control network, packaging hall Estado Activo Notas Address, PROFINET name, VLAN, switch port, and MAC were verified against the network drawing and configuration backup.
Dispositivo de red
Dispositivo de red Activo Nombre del dispositivo VFD-201 Modelo SINAMICS G120 Dirección IP 192.168.10.41
⌄
Detalles publicados Nombre del dispositivo VFD-201 Tipo de dispositivo drive Proveedor Siemens Modelo SINAMICS G120 Medio de red industrial_ethernet Protocolo profinet Rol del protocolo device Nombre PROFINET vfd-201 Dirección IP 192.168.10.41 Prefijo de subred 24 Máscara de subred 255.255.255.0 Puerta de enlace 192.168.10.1 VLAN 10 Puerto del switch 4 Dirección MAC AA:10:00:00:00:05 Ubicación Control network, packaging hall Estado Activo Notas Address, PROFINET name, VLAN, switch port, and MAC were verified against the network drawing and configuration backup.
Dispositivo de red
Dispositivo de red Activo Nombre del dispositivo VFD-202 Modelo SINAMICS G120 Dirección IP 192.168.10.42
⌄
Detalles publicados Nombre del dispositivo VFD-202 Tipo de dispositivo drive Proveedor Siemens Modelo SINAMICS G120 Medio de red industrial_ethernet Protocolo profinet Rol del protocolo device Nombre PROFINET vfd-202 Dirección IP 192.168.10.42 Prefijo de subred 24 Máscara de subred 255.255.255.0 Puerta de enlace 192.168.10.1 VLAN 10 Puerto del switch 5 Dirección MAC AA:10:00:00:00:06 Ubicación Control network, packaging hall Estado Activo Notas Address, PROFINET name, VLAN, switch port, and MAC were verified against the network drawing and configuration backup.
Dispositivo de red
Dispositivo de red Activo Nombre del dispositivo VISION-101 Modelo In-Sight 7905 Dirección IP 192.168.10.50
⌄
Detalles publicados Nombre del dispositivo VISION-101 Tipo de dispositivo vision_system Proveedor Cognex Modelo In-Sight 7905 Medio de red industrial_ethernet Protocolo profinet Rol del protocolo device Nombre PROFINET vision-101 Dirección IP 192.168.10.50 Prefijo de subred 24 Máscara de subred 255.255.255.0 Puerta de enlace 192.168.10.1 VLAN 10 Puerto del switch 6 Dirección MAC AA:10:00:00:00:07 Ubicación Control network, packaging hall Estado Activo Notas Address, PROFINET name, VLAN, switch port, and MAC were verified against the network drawing and configuration backup.
04 Ejecución y puesta en marcha 24 Registros publicados 29% Avance global⌄
7 Completados
1 En curso
1 Requieren atención
15 Sin iniciar
Comprobación E/S
Comprobación E/S Completado Completados 150 Total 150
100% ⌄
Detalles publicados Filtros de alcance Controller ulid: 01m3pcsrf84tw3bh5g3tv9swhz Estado Completado Total 150 Completados 150 Progreso 100.00 Inicio 29 sept 2026, 10:54 Finalización 30 sept 2026, 10:42
Lista de control
Lista de control Completado Inicio 29 sept 2026, 10:54
100% ⌄
Detalles publicados Versión de plantilla 1 Estado Completado Progreso 100.00 Inicio 29 sept 2026, 10:54 Finalización 30 sept 2026, 10:42
Lista de control
Lista de control Completado Inicio 29 sept 2026, 10:54
100% ⌄
Detalles publicados Versión de plantilla 1 Estado Completado Progreso 100.00 Inicio 29 sept 2026, 10:54 Finalización 30 sept 2026, 10:42
Lista de control
Lista de control Completado Inicio 29 sept 2026, 10:54
100% ⌄
Detalles publicados Versión de plantilla 1 Estado Completado Progreso 100.00 Inicio 29 sept 2026, 10:54 Finalización 30 sept 2026, 10:42
Lista de control
Lista de control Completado Inicio 29 sept 2026, 10:54
100% ⌄
Detalles publicados Versión de plantilla 1 Estado Completado Progreso 100.00 Inicio 29 sept 2026, 10:54 Finalización 30 sept 2026, 10:42
Lista de control
Lista de control Completado Inicio 29 sept 2026, 10:54
100% ⌄
Detalles publicados Versión de plantilla 1 Estado Completado Progreso 100.00 Inicio 29 sept 2026, 10:54 Finalización 30 sept 2026, 10:42
Lista de control
Lista de control Completado Inicio 29 sept 2026, 10:54
100% ⌄
Detalles publicados Versión de plantilla 1 Estado Completado Progreso 100.00 Inicio 29 sept 2026, 10:54 Finalización 30 sept 2026, 10:42
Deficiencia
Deficiencia open
0% ⌄
Detalles publicados Número P-0001 Descripción Check and complete both cable-end labels against the as-built drawing. Categoría installation Gravedad Media Prioridad Alta Estado open Fecha límite 10 jul 2026, 0:00 Resolución Corrective action is defined; final test and evidence are required after execution.
Deficiencia
Deficiencia En curso
0% ⌄
Detalles publicados Número P-0002 Descripción Align the local flow arrow with the P&ID and installed direction. Categoría mechanical Gravedad Baja Prioridad Media Estado En curso Fecha límite 11 jul 2026, 0:00 Resolución Corrective action is defined; final test and evidence are required after execution.
Deficiencia
Deficiencia ready_for_review
0% ⌄
Detalles publicados Número P-0003 Descripción Record ramp and current-limit parameters in the final revision after the product test. Categoría commissioning Gravedad Media Prioridad Alta Estado ready_for_review Fecha límite 12 jul 2026, 0:00 Resolución Corrective action is defined; final test and evidence are required after execution.
Deficiencia
Deficiencia Bloqueado
0% ⌄
Detalles publicados Número P-0004 Descripción The installed gland lacks the required washdown protection; replace and photograph it. Categoría electrical Gravedad Alta Prioridad Urgente Estado Bloqueado Fecha límite 13 jul 2026, 0:00 Resolución Corrective action is defined; final test and evidence are required after execution.
Deficiencia
Deficiencia closed
0% ⌄
Detalles publicados Número P-0005 Descripción Remove the disabled alarm from the operator view and record the test result. Categoría software Gravedad Baja Prioridad Baja Estado closed Fecha límite 14 jul 2026, 0:00 Resolución Correction completed, retest passed, image checked, and item closed. Cierre 30 sept 2026, 10:42
▤
Registro relacionado Complete checkout of 150 production-line I/O points · DI-001
◷
Fecha de carga 29 sept 2026, 10:54
□
Tamaño del archivo 0.00 MB
▤
Registro relacionado Complete checkout of 150 production-line I/O points · DO-002
◷
Fecha de carga 29 sept 2026, 10:54
□
Tamaño del archivo 0.00 MB
▤
Registro relacionado Complete checkout of 150 production-line I/O points · AI-003
◷
Fecha de carga 29 sept 2026, 10:54
□
Tamaño del archivo 0.00 MB
▤
Registro relacionado Completed report · Pre-commissioning readiness
◷
Fecha de carga 29 sept 2026, 10:54
□
Tamaño del archivo 0.00 MB
▤
Registro relacionado Completed report · Factory acceptance test
◷
Fecha de carga 29 sept 2026, 10:54
□
Tamaño del archivo 0.00 MB
▤
Registro relacionado Completed report · Site acceptance test
◷
Fecha de carga 29 sept 2026, 10:54
□
Tamaño del archivo 0.00 MB
▤
Registro relacionado Completed report · Network commissioning
◷
Fecha de carga 29 sept 2026, 10:54
□
Tamaño del archivo 0.00 MB
▤
Registro relacionado P-0001 · Complete the cabinet network-cable label · Managed control-network switch
◷
Fecha de carga 29 sept 2026, 10:54
□
Tamaño del archivo 0.00 MB
▤
Registro relacionado P-0002 · Correct the flow arrow on valve XV-101 · Feed emergency shutoff valve
◷
Fecha de carga 29 sept 2026, 10:54
□
Tamaño del archivo 0.00 MB
▤
Registro relacionado P-0003 · Record the final outfeed-drive parameters · Outfeed conveyor drive
◷
Fecha de carga 29 sept 2026, 10:54
□
Tamaño del archivo 0.00 MB
▤
Registro relacionado P-0004 · Replace the pressure analog-cable gland · Line pressure transmitter
◷
Fecha de carga 29 sept 2026, 10:54
□
Tamaño del archivo 0.00 MB
▤
Registro relacionado P-0005 · Remove the obsolete HMI alarm · Main operator panel
◷
Fecha de carga 29 sept 2026, 10:54
□
Tamaño del archivo 0.00 MB
06 Control de revisiones 10 Registros publicados ⌄
▤
Control de revisiones
Archivos del proyecto
Archivos técnicos, documentos y recursos aprobados disponibles en esta publicación.
10
10 archivos publicados
Tamaño publicado: 0.01 MB
Proyectos PLC
2
HMI y SCADA
1
Otros archivos
7
Proyectos PLC 2
▤
Registro relacionado AX-SMP-IO-001 · Approved I/O register
◷
Fecha de carga 29 sept 2026, 10:54
□
Tamaño del archivo 0.01 MB
▤
Registro relacionado AX-SMP-PLC-001 · PLC program recovery guide
◷
Fecha de carga 29 sept 2026, 10:54
□
Tamaño del archivo 0.00 MB
HMI y SCADA 1
▤
Registro relacionado AX-SMP-HMI-001 · HMI configuration definition
◷
Fecha de carga 29 sept 2026, 10:54
□
Tamaño del archivo 0.00 MB
Otros archivos 7
▤
Registro relacionado AX-SMP-NET-001 · Industrial network plan and settings
◷
Fecha de carga 29 sept 2026, 10:54
□
Tamaño del archivo 0.01 MB
▤
Registro relacionado AX-SMP-EL-001 · Main control cabinet single-line diagram
◷
Fecha de carga 29 sept 2026, 10:54
□
Tamaño del archivo 0.00 MB
▤
Registro relacionado AX-SMP-FAT-001 · FAT test report
◷
Fecha de carga 29 sept 2026, 10:54
□
Tamaño del archivo 0.00 MB
▤
Registro relacionado AX-SMP-SAT-001 · SAT test report
◷
Fecha de carga 29 sept 2026, 10:54
□
Tamaño del archivo 0.00 MB
▤
Registro relacionado AX-SMP-BOM-001 · Final project bill of materials
◷
Fecha de carga 29 sept 2026, 10:54
□
Tamaño del archivo 0.00 MB
▤
Registro relacionado AX-SMP-COM-001 · Commissioning event report
◷
Fecha de carga 29 sept 2026, 10:54
□
Tamaño del archivo 0.00 MB
▤
Registro relacionado AX-SMP-MTG-001 · Project handover meeting calendar
◷
Fecha de carga 29 sept 2026, 10:54
□
Tamaño del archivo 0.00 MB
07 Ciclo de cambios 46 Registros publicados ⌄
Solicitud de cambio
Solicitud de cambio Completado Número de solicitud MOC-SAMPLE-001 Nivel de riesgo Alta
⌄
Detalles publicados Número de solicitud MOC-SAMPLE-001 Alcance Packaging Line 2 main panel safety relay, mapped inputs, controlled drawings, and acceptance evidence. Motivo The installed relay is obsolete and no longer supported by the manufacturer. Nivel de riesgo Alta Controles y detalles del riesgo Lockout, point-to-point verification, witnessed stop-time testing, and documented rollback are mandatory. Impacto Safety: Safety is unavailable during the controlled outage.; Production: One planned shift of downtime.; Technical: Safety I/O mapping and the electrical drawing revision change together.; Schedule: Execute in the approved maintenance window and issue the report within one working day.; Cost: Within the approved sample budget without a separate change order. Cambio propuesto Install the approved relay, verify every safety input and output, and designate the tested drawing as-built. Prioridad Alta Estado Completado Decisión de aprobación Aprobado Notas de aprobación Approved as part of the localized demonstration workflow. Solicitado el 29 sept 2026, 10:54 Aprobado el 29 sept 2026, 10:54 Notas de implementación Demonstration implementation evidence is ready for review. Finalización 29 sept 2026, 10:54
Solicitud de cambio
Solicitud de cambio Completado Número de solicitud MOC-SAMPLE-002 Nivel de riesgo Media
⌄
Detalles publicados Número de solicitud MOC-SAMPLE-002 Alcance Control software, related documents, execution tests, backup, and operator training. Motivo Reduce the broadcast domain and separate engineering traffic. Nivel de riesgo Media Controles y detalles del riesgo Safety assessment, rollback copy, lockout/tagout, point-to-point testing, and client approval are mandatory. Impacto Safety: Preventive safety controls are assessed and recorded.; Production: A planned 30-minute network interruption.; Technical: Logic, settings, documents, installed revision, and rollback plan are updated together.; Schedule: Execute in the approved maintenance window and issue the report within one working day.; Cost: Within the approved sample budget without a separate change order. Cambio propuesto Implement in the controlled engineering environment, peer-review, simulate, back up, then test and record on site. Prioridad Media Estado Completado Decisión de aprobación Aprobado Notas de aprobación Scope, risks, test plan, and rollback path were reviewed and approved. Solicitado el 29 sept 2026, 10:54 Aprobado el 29 sept 2026, 10:54 Notas de implementación The approved change was implemented, tests recorded, installed revision verified, and as-built documents updated. Finalización 29 sept 2026, 10:54
Solicitud de cambio
Solicitud de cambio Completado Número de solicitud MOC-SAMPLE-003 Nivel de riesgo Baja
⌄
Detalles publicados Número de solicitud MOC-SAMPLE-003 Alcance Control software, related documents, execution tests, backup, and operator training. Motivo Stabilize indication and prevent nuisance alarms. Nivel de riesgo Baja Controles y detalles del riesgo Safety assessment, rollback copy, lockout/tagout, point-to-point testing, and client approval are mandatory. Impacto Safety: Preventive safety controls are assessed and recorded.; Production: No production stop; controlled online test.; Technical: Logic, settings, documents, installed revision, and rollback plan are updated together.; Schedule: Execute in the approved maintenance window and issue the report within one working day.; Cost: Within the approved sample budget without a separate change order. Cambio propuesto Implement in the controlled engineering environment, peer-review, simulate, back up, then test and record on site. Prioridad Media Estado Completado Decisión de aprobación Aprobado Notas de aprobación Scope, risks, test plan, and rollback path were reviewed and approved. Solicitado el 29 sept 2026, 10:54 Aprobado el 29 sept 2026, 10:54 Notas de implementación The approved change was implemented, tests recorded, installed revision verified, and as-built documents updated. Finalización 29 sept 2026, 10:54
Solicitud de cambio
Solicitud de cambio Completado Número de solicitud MOC-SAMPLE-004 Nivel de riesgo Media
⌄
Detalles publicados Número de solicitud MOC-SAMPLE-004 Alcance Control software, related documents, execution tests, backup, and operator training. Motivo Prevent product accumulation during line startup. Nivel de riesgo Media Controles y detalles del riesgo Safety assessment, rollback copy, lockout/tagout, point-to-point testing, and client approval are mandatory. Impacto Safety: Preventive safety controls are assessed and recorded.; Production: Dry test followed by a product test.; Technical: Logic, settings, documents, installed revision, and rollback plan are updated together.; Schedule: Execute in the approved maintenance window and issue the report within one working day.; Cost: Within the approved sample budget without a separate change order. Cambio propuesto Implement in the controlled engineering environment, peer-review, simulate, back up, then test and record on site. Prioridad Alta Estado Completado Decisión de aprobación Aprobado Notas de aprobación Scope, risks, test plan, and rollback path were reviewed and approved. Solicitado el 29 sept 2026, 10:54 Aprobado el 29 sept 2026, 10:54 Notas de implementación The approved change was implemented, tests recorded, installed revision verified, and as-built documents updated. Finalización 29 sept 2026, 10:54
Solicitud de cambio
Solicitud de cambio Completado Número de solicitud MOC-SAMPLE-005 Nivel de riesgo Baja
⌄
Detalles publicados Número de solicitud MOC-SAMPLE-005 Alcance Control software, related documents, execution tests, backup, and operator training. Motivo Give maintenance faster access to asset status. Nivel de riesgo Baja Controles y detalles del riesgo Safety assessment, rollback copy, lockout/tagout, point-to-point testing, and client approval are mandatory. Impacto Safety: Preventive safety controls are assessed and recorded.; Production: No effect on PLC logic or safety.; Technical: Logic, settings, documents, installed revision, and rollback plan are updated together.; Schedule: Execute in the approved maintenance window and issue the report within one working day.; Cost: Within the approved sample budget without a separate change order. Cambio propuesto Implement in the controlled engineering environment, peer-review, simulate, back up, then test and record on site. Prioridad Baja Estado Completado Decisión de aprobación Aprobado Notas de aprobación Scope, risks, test plan, and rollback path were reviewed and approved. Solicitado el 29 sept 2026, 10:54 Aprobado el 29 sept 2026, 10:54 Notas de implementación The approved change was implemented, tests recorded, installed revision verified, and as-built documents updated. Finalización 29 sept 2026, 10:54
Evento del ciclo
Se creó la solicitud de modificación MOC-SAMPLE-001. Fecha del evento 29 sept 2026, 10:54
⌄
Detalles publicados Fecha del evento 29 sept 2026, 10:54
Evento del ciclo
La solicitud MOC-SAMPLE-001 pasó de draft a submitted. Fecha del evento 29 sept 2026, 10:54
⌄
Detalles publicados Fecha del evento 29 sept 2026, 10:54
Evento del ciclo
La solicitud MOC-SAMPLE-001 pasó de submitted a under_review. Fecha del evento 29 sept 2026, 10:54
⌄
Detalles publicados Fecha del evento 29 sept 2026, 10:54
Evento del ciclo
La solicitud MOC-SAMPLE-001 pasó de under_review a approved. Fecha del evento 29 sept 2026, 10:54
⌄
Detalles publicados Fecha del evento 29 sept 2026, 10:54
Evento del ciclo
La solicitud MOC-SAMPLE-001 pasó de approved a implementing. Fecha del evento 29 sept 2026, 10:54
⌄
Detalles publicados Fecha del evento 29 sept 2026, 10:54
Evento del ciclo
La solicitud MOC-SAMPLE-001 pasó de implementing a completed. Fecha del evento 29 sept 2026, 10:54
⌄
Detalles publicados Fecha del evento 29 sept 2026, 10:54
Evento del ciclo
Se creó la solicitud de modificación MOC-SAMPLE-002. Fecha del evento 29 sept 2026, 10:54
⌄
Detalles publicados Fecha del evento 29 sept 2026, 10:54
Evento del ciclo
La solicitud MOC-SAMPLE-002 pasó de draft a submitted. Fecha del evento 29 sept 2026, 10:54
⌄
Detalles publicados Fecha del evento 29 sept 2026, 10:54
Evento del ciclo
La solicitud MOC-SAMPLE-002 pasó de submitted a under_review. Fecha del evento 29 sept 2026, 10:54
⌄
Detalles publicados Fecha del evento 29 sept 2026, 10:54
Evento del ciclo
La solicitud MOC-SAMPLE-002 pasó de under_review a approved. Fecha del evento 29 sept 2026, 10:54
⌄
Detalles publicados Fecha del evento 29 sept 2026, 10:54
Evento del ciclo
La solicitud MOC-SAMPLE-002 pasó de approved a implementing. Fecha del evento 29 sept 2026, 10:54
⌄
Detalles publicados Fecha del evento 29 sept 2026, 10:54
Evento del ciclo
La solicitud MOC-SAMPLE-002 pasó de implementing a completed. Fecha del evento 29 sept 2026, 10:54
⌄
Detalles publicados Fecha del evento 29 sept 2026, 10:54
Evento del ciclo
Se creó la solicitud de modificación MOC-SAMPLE-003. Fecha del evento 29 sept 2026, 10:54
⌄
Detalles publicados Fecha del evento 29 sept 2026, 10:54
Evento del ciclo
La solicitud MOC-SAMPLE-003 pasó de draft a submitted. Fecha del evento 29 sept 2026, 10:54
⌄
Detalles publicados Fecha del evento 29 sept 2026, 10:54
Evento del ciclo
La solicitud MOC-SAMPLE-003 pasó de submitted a under_review. Fecha del evento 29 sept 2026, 10:54
⌄
Detalles publicados Fecha del evento 29 sept 2026, 10:54
Evento del ciclo
La solicitud MOC-SAMPLE-003 pasó de under_review a approved. Fecha del evento 29 sept 2026, 10:54
⌄
Detalles publicados Fecha del evento 29 sept 2026, 10:54
Evento del ciclo
La solicitud MOC-SAMPLE-003 pasó de approved a implementing. Fecha del evento 29 sept 2026, 10:54
⌄
Detalles publicados Fecha del evento 29 sept 2026, 10:54
Evento del ciclo
La solicitud MOC-SAMPLE-003 pasó de implementing a completed. Fecha del evento 29 sept 2026, 10:54
⌄
Detalles publicados Fecha del evento 29 sept 2026, 10:54
Evento del ciclo
Se creó la solicitud de modificación MOC-SAMPLE-004. Fecha del evento 29 sept 2026, 10:54
⌄
Detalles publicados Fecha del evento 29 sept 2026, 10:54
Evento del ciclo
La solicitud MOC-SAMPLE-004 pasó de draft a submitted. Fecha del evento 29 sept 2026, 10:54
⌄
Detalles publicados Fecha del evento 29 sept 2026, 10:54
Evento del ciclo
La solicitud MOC-SAMPLE-004 pasó de submitted a under_review. Fecha del evento 29 sept 2026, 10:54
⌄
Detalles publicados Fecha del evento 29 sept 2026, 10:54
Evento del ciclo
La solicitud MOC-SAMPLE-004 pasó de under_review a approved. Fecha del evento 29 sept 2026, 10:54
⌄
Detalles publicados Fecha del evento 29 sept 2026, 10:54
Evento del ciclo
La solicitud MOC-SAMPLE-004 pasó de approved a implementing. Fecha del evento 29 sept 2026, 10:54
⌄
Detalles publicados Fecha del evento 29 sept 2026, 10:54
Evento del ciclo
La solicitud MOC-SAMPLE-004 pasó de implementing a completed. Fecha del evento 29 sept 2026, 10:54
⌄
Detalles publicados Fecha del evento 29 sept 2026, 10:54
Evento del ciclo
Se creó la solicitud de modificación MOC-SAMPLE-005. Fecha del evento 29 sept 2026, 10:54
⌄
Detalles publicados Fecha del evento 29 sept 2026, 10:54
Evento del ciclo
La solicitud MOC-SAMPLE-005 pasó de draft a submitted. Fecha del evento 29 sept 2026, 10:54
⌄
Detalles publicados Fecha del evento 29 sept 2026, 10:54
Evento del ciclo
La solicitud MOC-SAMPLE-005 pasó de submitted a under_review. Fecha del evento 29 sept 2026, 10:54
⌄
Detalles publicados Fecha del evento 29 sept 2026, 10:54
Evento del ciclo
La solicitud MOC-SAMPLE-005 pasó de under_review a approved. Fecha del evento 29 sept 2026, 10:54
⌄
Detalles publicados Fecha del evento 29 sept 2026, 10:54
Evento del ciclo
La solicitud MOC-SAMPLE-005 pasó de approved a implementing. Fecha del evento 29 sept 2026, 10:54
⌄
Detalles publicados Fecha del evento 29 sept 2026, 10:54
Evento del ciclo
La solicitud MOC-SAMPLE-005 pasó de implementing a completed. Fecha del evento 29 sept 2026, 10:54
⌄
Detalles publicados Fecha del evento 29 sept 2026, 10:54
Evento del ciclo
Se vinculó Controlled revision associated with the change a la solicitud MOC-SAMPLE-001. Fecha del evento 29 sept 2026, 10:54
⌄
Detalles publicados Fecha del evento 29 sept 2026, 10:54
Evento del ciclo
Se vinculó Post-change test and acceptance report a la solicitud MOC-SAMPLE-001. Fecha del evento 29 sept 2026, 10:54
⌄
Detalles publicados Fecha del evento 29 sept 2026, 10:54
Evento del ciclo
Se vinculó Controlled revision associated with the change a la solicitud MOC-SAMPLE-002. Fecha del evento 29 sept 2026, 10:54
⌄
Detalles publicados Fecha del evento 29 sept 2026, 10:54
Evento del ciclo
Se vinculó Post-change test and acceptance report a la solicitud MOC-SAMPLE-002. Fecha del evento 29 sept 2026, 10:54
⌄
Detalles publicados Fecha del evento 29 sept 2026, 10:54
Evento del ciclo
Se vinculó Controlled revision associated with the change a la solicitud MOC-SAMPLE-003. Fecha del evento 29 sept 2026, 10:54
⌄
Detalles publicados Fecha del evento 29 sept 2026, 10:54
Evento del ciclo
Se vinculó Post-change test and acceptance report a la solicitud MOC-SAMPLE-003. Fecha del evento 29 sept 2026, 10:54
⌄
Detalles publicados Fecha del evento 29 sept 2026, 10:54
Evento del ciclo
Se vinculó Controlled revision associated with the change a la solicitud MOC-SAMPLE-004. Fecha del evento 29 sept 2026, 10:54
⌄
Detalles publicados Fecha del evento 29 sept 2026, 10:54
Evento del ciclo
Se vinculó Post-change test and acceptance report a la solicitud MOC-SAMPLE-004. Fecha del evento 29 sept 2026, 10:54
⌄
Detalles publicados Fecha del evento 29 sept 2026, 10:54
Evento del ciclo
Se vinculó Controlled revision associated with the change a la solicitud MOC-SAMPLE-005. Fecha del evento 29 sept 2026, 10:54
⌄
Detalles publicados Fecha del evento 29 sept 2026, 10:54
Evento del ciclo
Se vinculó Post-change test and acceptance report a la solicitud MOC-SAMPLE-005. Fecha del evento 29 sept 2026, 10:54
⌄
Detalles publicados Fecha del evento 29 sept 2026, 10:54
Evento del ciclo
Se creó el pasaporte de máquina SAMPLE-LINE-01. Fecha del evento 29 sept 2026, 10:54
⌄
Detalles publicados Fecha del evento 29 sept 2026, 10:54